IBM 86625RY Hardware Maintenance Manual - Page 305
VRM 2 or VRM 1, Error Code/Symptom
UPC - 087944501855
View all IBM 86625RY manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 305 highlights
Error Code/Symptom 201-XXX-004 (Failed Memory test, see"Memory settings" on page 30 ) 201-XXX-005 (Failed Memory test, see"Memory settings" on page 30 ) 201-XXX-006 (Failed Memory test, see"Memory settings" on page 30 ) 201-XXX-007 (Failed Memory test, see"Memory settings" on page 30 ) 201-XXX-008 (Failed Memory test, see"Memory settings" on page 30 ) 201-XXX-999 (Multiple DIMM failure, see error text.) 202-XXX-001 (Failed System Cache test) 202-XXX-002 (Failed System Cache test) 202-XXX-003 (Failed System Cache test) 202-XXX-004 (Failed System Cache test) 206-XXX-000 (Failed Diskette Drive test) 215-XXX-000 (Failed IDE CD-ROM test) 217-XXX-000 (Failed BIOS Fixed Disk test) Note If RAID is configured, the fixed disk number refers to the RAID logical array. FRU/Action 1. DIMM Location J4 1. DIMM Location J5 1. DIMM Location J6 1. DIMM Location J7 1. DIMM Location J8 1. See error text for failing DIMMs 1. VRM 2 or VRM 1 2. Microprocessor CPU 1 1. VRM 2 or VRM 3 2. Microprocessor CPU 2 1. VRM 5 or VRM 4 2. Microprocessor CPU 3 1. VRM 5 or VRM 6 2. Microprocessor CPU 4 1. Cable 2. Diskette Drive 3. System Board 1. CD-ROM Drive Cables 2. CD-ROM Drive 3. System Board 1. Fixed Disk 1 Netfinity 5500 M20 - Type 8662 297