IBM 887022X Maintenance Manual - Page 222

code/symptom

Page 222 highlights

Note: See Chapter 8, "Parts listing, Type 8870," on page 249 to determine which components are replaceable by the customer, and which components should be replaced by an IBM field service technician. Error code/symptom FRU/action 015-xxx-198 (Remote Supervisor Adapter II installed) or (USB device connected during USB test) 1. If Remote Supervisor Adapter II is installed as an option, remove it and rerun test. Note: If Remote Supervisor Adapter II is present as a standard installation, do not remove it; the test cannot be run. 2. Remove USB devices and rerun test. 3. I/O board. 020-xxx-000 (Failed PCI Interface test) 1. PCI-X board 2. I/O board 020-xxx-001 (Failed Hot-Swap Slot 1 PCI 1. PCI Hot-Swap Latch assembly Latch test) 2. PCI-X board 020-xxx-002 (Failed Hot-Swap Slot 2 PCI 1. PCI Hot-Swap Latch assembly Latch test) 2. PCI-X board 020-xxx-003 (Failed Hot-Swap Slot 3 PCI 1. PCI Hot-Swap Latch assembly Latch test) 2. PCI-X board 020-xxx-004 (Failed Hot-Swap Slot 4 PCI 1. PCI Hot-Swap Latch assembly Latch test) 2. PCI-X board 020-xxx-005 (Failed Hot-Swap Slot 5 PCI 1. PCI Hot-Swap Latch assembly Latch test) 2. PCI-X board 020-xxx-006 (Failed Hot-Swap Slot 6 PCI 1. PCI Hot-Swap Latch assembly Latch test) 2. PCI-X board 030-xxx-000 (Failed Internal SCSI interface test) 1. Make sure SCSI is not enabled, rerun test. 2. I/O board. 030-xxx-00n (Failed SCSI test on PCI slot n. Check system error log before replacing a FRU.) Adapter in slot n 035-002-0nn (ServeRAID interface timeout) 1. ServeRAID controller may not be configured properly. Obtain the basic and extended configuration status bytes and refer to the ServeRAID Hardware Maintenance Manual for more information. 2. Cable. 3. SCSI backplane. 4. ServeRAID controller. 035-253-0nn (ServeRAID controller 0nn initialization failure; 0nn = the controller number) 1. ServeRAID controller may not be configured properly. Obtain the basic and extended configuration status bytes and refer to the ServeRAID Hardware Maintenance Manual for more information. 2. Cable. 3. SCSI backplane. 4. ServeRAID controller. 035-253-s99 (RAID adapter initialization failure) 1. ServeRAID adapter 2. SCSI cable 035-254-0nn (Setup error - unable to allocate memory to run test.) Check system resources. 212 xSeries 445 Type 8870: Hardware Maintenance Manual and Troubleshooting Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302
  • 303
  • 304
  • 305
  • 306
  • 307
  • 308
  • 309
  • 310
  • 311
  • 312
  • 313
  • 314
  • 315
  • 316
  • 317
  • 318
  • 319
  • 320
  • 321
  • 322
  • 323
  • 324

Note:
See
Chapter
8,
“Parts
listing,
Type
8870,”
on
page
249
to
determine
which
components
are
replaceable
by
the
customer,
and
which
components
should
be
replaced
by
an
IBM
field
service
technician.
Error
code/symptom
FRU/action
015-xxx-198
(Remote
Supervisor
Adapter
II
installed)
or
(USB
device
connected
during
USB
test)
1.
If
Remote
Supervisor
Adapter
II
is
installed
as
an
option,
remove
it
and
rerun
test.
Note:
If
Remote
Supervisor
Adapter
II
is
present
as
a
standard
installation,
do
not
remove
it;
the
test
cannot
be
run.
2.
Remove
USB
devices
and
rerun
test.
3.
I/O
board.
020-xxx-000
(Failed
PCI
Interface
test)
1.
PCI-X
board
2.
I/O
board
020-xxx-001
(Failed
Hot-Swap
Slot
1
PCI
Latch
test)
1.
PCI
Hot-Swap
Latch
assembly
2.
PCI-X
board
020-xxx-002
(Failed
Hot-Swap
Slot
2
PCI
Latch
test)
1.
PCI
Hot-Swap
Latch
assembly
2.
PCI-X
board
020-xxx-003
(Failed
Hot-Swap
Slot
3
PCI
Latch
test)
1.
PCI
Hot-Swap
Latch
assembly
2.
PCI-X
board
020-xxx-004
(Failed
Hot-Swap
Slot
4
PCI
Latch
test)
1.
PCI
Hot-Swap
Latch
assembly
2.
PCI-X
board
020-xxx-005
(Failed
Hot-Swap
Slot
5
PCI
Latch
test)
1.
PCI
Hot-Swap
Latch
assembly
2.
PCI-X
board
020-xxx-006
(Failed
Hot-Swap
Slot
6
PCI
Latch
test)
1.
PCI
Hot-Swap
Latch
assembly
2.
PCI-X
board
030-xxx-000
(Failed
Internal
SCSI
interface
test)
1.
Make
sure
SCSI
is
not
enabled,
rerun
test.
2.
I/O
board.
030-xxx-00n
(Failed
SCSI
test
on
PCI
slot
n.
Check
system
error
log
before
replacing
a
FRU.)
Adapter
in
slot
n
035-002-0nn
(ServeRAID
interface
timeout)
1.
ServeRAID
controller
may
not
be
configured
properly.
Obtain
the
basic
and
extended
configuration
status
bytes
and
refer
to
the
ServeRAID
Hardware
Maintenance
Manual
for
more
information.
2.
Cable.
3.
SCSI
backplane.
4.
ServeRAID
controller.
035-253-0nn
(ServeRAID
controller
0nn
initialization
failure;
0nn
=
the
controller
number)
1.
ServeRAID
controller
may
not
be
configured
properly.
Obtain
the
basic
and
extended
configuration
status
bytes
and
refer
to
the
ServeRAID
Hardware
Maintenance
Manual
for
more
information.
2.
Cable.
3.
SCSI
backplane.
4.
ServeRAID
controller.
035-253-s99
(RAID
adapter
initialization
failure)
1.
ServeRAID
adapter
2.
SCSI
cable
035-254-0nn
(Setup
error
-
unable
to
allocate
memory
to
run
test.)
Check
system
resources.
212
xSeries
445
Type
8870:
Hardware
Maintenance
Manual
and
Troubleshooting
Guide