IBM 887022X Maintenance Manual - Page 222
code/symptom
![]() |
UPC - 000435151957
View all IBM 887022X manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 222 highlights
Note: See Chapter 8, "Parts listing, Type 8870," on page 249 to determine which components are replaceable by the customer, and which components should be replaced by an IBM field service technician. Error code/symptom FRU/action 015-xxx-198 (Remote Supervisor Adapter II installed) or (USB device connected during USB test) 1. If Remote Supervisor Adapter II is installed as an option, remove it and rerun test. Note: If Remote Supervisor Adapter II is present as a standard installation, do not remove it; the test cannot be run. 2. Remove USB devices and rerun test. 3. I/O board. 020-xxx-000 (Failed PCI Interface test) 1. PCI-X board 2. I/O board 020-xxx-001 (Failed Hot-Swap Slot 1 PCI 1. PCI Hot-Swap Latch assembly Latch test) 2. PCI-X board 020-xxx-002 (Failed Hot-Swap Slot 2 PCI 1. PCI Hot-Swap Latch assembly Latch test) 2. PCI-X board 020-xxx-003 (Failed Hot-Swap Slot 3 PCI 1. PCI Hot-Swap Latch assembly Latch test) 2. PCI-X board 020-xxx-004 (Failed Hot-Swap Slot 4 PCI 1. PCI Hot-Swap Latch assembly Latch test) 2. PCI-X board 020-xxx-005 (Failed Hot-Swap Slot 5 PCI 1. PCI Hot-Swap Latch assembly Latch test) 2. PCI-X board 020-xxx-006 (Failed Hot-Swap Slot 6 PCI 1. PCI Hot-Swap Latch assembly Latch test) 2. PCI-X board 030-xxx-000 (Failed Internal SCSI interface test) 1. Make sure SCSI is not enabled, rerun test. 2. I/O board. 030-xxx-00n (Failed SCSI test on PCI slot n. Check system error log before replacing a FRU.) Adapter in slot n 035-002-0nn (ServeRAID interface timeout) 1. ServeRAID controller may not be configured properly. Obtain the basic and extended configuration status bytes and refer to the ServeRAID Hardware Maintenance Manual for more information. 2. Cable. 3. SCSI backplane. 4. ServeRAID controller. 035-253-0nn (ServeRAID controller 0nn initialization failure; 0nn = the controller number) 1. ServeRAID controller may not be configured properly. Obtain the basic and extended configuration status bytes and refer to the ServeRAID Hardware Maintenance Manual for more information. 2. Cable. 3. SCSI backplane. 4. ServeRAID controller. 035-253-s99 (RAID adapter initialization failure) 1. ServeRAID adapter 2. SCSI cable 035-254-0nn (Setup error - unable to allocate memory to run test.) Check system resources. 212 xSeries 445 Type 8870: Hardware Maintenance Manual and Troubleshooting Guide
![](/manual_guide/products/ibm-887022x-maintenance-manual-031fc62/222.png)