IBM 88772ru User Guide

IBM 88772ru - Servers System X3755 Opteron 2.2ghz Manual

IBM 88772ru manual content summary:

  • IBM 88772ru | User Guide - Page 1
    IBM System x3755 Type 8877 User's Guide
  • IBM 88772ru | User Guide - Page 2
  • IBM 88772ru | User Guide - Page 3
    IBM System x3755 Type 8877 User's Guide
  • IBM 88772ru | User Guide - Page 4
    Note: Before using this information and the product it supports, read the general information in "Notices," on page 75. First Edition (July 2006) © Copyright International Business Machines Corporation 2006. All rights reserved. US Government Users
  • IBM 88772ru | User Guide - Page 5
    documentation 1 Notices and statements in this document 2 Features and specifications 3 What your server offers 4 Reliability, availability, and serviceability 6 IBM Director 7 The UpdateXpress program 7 Server controls, connectors, LEDs, and power 8 Front view 8 Rear view 9 Server power
  • IBM 88772ru | User Guide - Page 6
    Using the IBM ServeRAID Configuration Utility program 66 Starting the IBM ServeRAID Configuration Utility program 66 IBM ServeRAID Configuration II SlimLine firmware 70 Completing the setup 71 Chapter 4. Updating IBM Director 73 Appendix. Notices 75 Trademarks 75 Important notes 76 Product
  • IBM 88772ru | User Guide - Page 7
    , leggere le Informazioni sulla Sicurezza. Les sikkerhetsinformasjonen (Safety Information) før du installerer dette produktet. Antes de instalar este produto, leia as Informações sobre Segurança. © Copyright IBM Corp. 2006 v
  • IBM 88772ru | User Guide - Page 8
    book under statement 1. Be sure to read all caution and danger statements in this documentation before performing the instructions. Read any additional safety information that comes with the server or optional device before you install the device. vi IBM System x3755 Type 8877: User's Guide
  • IBM 88772ru | User Guide - Page 9
    damage. v Disconnect the attached power cords, telecommunications systems, networks, and modems before you open the device covers, unless instructed otherwise in the installation and configuration procedures. v Connect and disconnect cables as described in the following table when installing, moving
  • IBM 88772ru | User Guide - Page 10
    of the laser product could result in exposure to hazardous laser radiation. There are no serviceable parts inside the device. v Use of controls or adjustments or performance of procedures other optical instruments, and avoid direct exposure to the beam. viii IBM System x3755 Type 8877: User's Guide
  • IBM 88772ru | User Guide - Page 11
    Statement 4: ≥ 18 kg (39.7 lb) ≥ 32 kg (70.5 lb) CAUTION: Use safe practices when lifting. Statement 5: ≥ 55 kg (121.2 lb) CAUTION: The power control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device. The device also
  • IBM 88772ru | User Guide - Page 12
    parts inside these components. If you suspect a problem with one of these parts, contact a service technician. Statement 26: CAUTION: Do not place any object on top of rack-mounted devices. Statement 27: CAUTION: Hazardous moving parts are nearby. x IBM System x3755 Type 8877: User's Guide
  • IBM 88772ru | User Guide - Page 13
    and getting service and assistance, see the Warranty and Support Information document. The server contains IBM X-Architecture Instructions This printed document contain instructions for installing the server in a rack. v Problem Determination and Service Guide This document is in PDF on the IBM
  • IBM 88772ru | User Guide - Page 14
    document. 1. Go to http://www.ibm.com/servers/eserver/support/xseries/index.html. 2. From the problem situations. v Attention: These notices indicate potential damage to programs, devices, or data. An attention notice is placed just before the instruction IBM System x3755 Type 8877: User's Guide
  • IBM 88772ru | User Guide - Page 15
    (kVA): (BMC) - Minimum: 0.20 kVA v Service processor support for Remote - Maximum: 1.93 kVA Supervisor Adapter II levels indicate an upper Environment: v Air temperature: limit, below which a large number of computers will operate. - Server on: 10° to 35°C (50.0° to 95.0°F); altitude:
  • IBM 88772ru | User Guide - Page 16
    you diagnose the problem and records the errors service processor refers to the baseboard management controller or the optional Remote Supervisor Adapter II SlimLine. v IBM Director IBM capacity The server supports up to 128 GB of system memory. The memory controller supports error correcting code
  • IBM 88772ru | User Guide - Page 17
    diagnostics in the Installation Guide and the Problem Determination and Service Guide. v PowerExecutive™ PowerExecutive is an IBM Director extension that measures and (RAID) configurations. v Symmetric multiprocessing (SMP) The server supports up to four AMD Opteron dual-core microprocessors. If the
  • IBM 88772ru | User Guide - Page 18
    support for the Trusted Computing Group (TCG) specification. Reliability, availability, and serviceability Three important computer design features are reliability, availability, and serviceability v Remote system problem-determination support v ROM-based IBM System x3755 Type 8877: User's Guide
  • IBM 88772ru | User Guide - Page 19
    /site.wss/document.do?lndocid=MIGR-61788. It is updated every 6 to 8 weeks. v Support for IBM and non-IBM servers, desktop computers, workstations, and notebook computers. v Support for systems-management industry standards. v Integration into leading workgroup and enterprise systems-management
  • IBM 88772ru | User Guide - Page 20
    on the operator information panel: Power-control button: Press this button to turn the server on and off manually. A power-control-button shield comes with the server. Power-on LED: When this LED is lit , it indicates that a SAS hard disk drive is in use. 8 IBM System x3755 Type 8877: User's Guide
  • IBM 88772ru | User Guide - Page 21
    Rear view Locator LED: When this LED is lit, it has been lit remotely by the system administrator to aid in visually locating the server. Information LED: When this LED is lit, it indicates that a noncritical event has occurred. An LED on the light path diagnostics panel is also lit to help isolate
  • IBM 88772ru | User Guide - Page 22
    BMC can take control of the shared serial port to perform text console redirection and to redirect serial traffic, using Serial over LAN (SOL). 10 IBM System x3755 Type 8877: User's Guide
  • IBM 88772ru | User Guide - Page 23
    systems-management software can turn on the server. v If your operating system supports the Wake on LAN feature, the Wake on LAN feature can turn on leave it connected to ac power, the server can respond to requests from the service processor, such as a remote request to turn on the server. While the
  • IBM 88772ru | User Guide - Page 24
    server from the operating system, if your operating system supports this feature. After an orderly shutdown of the orderly shutdown of the operating system and turn off the server, if your operating system supports this feature. v If the operating system stops functioning, you can press and hold
  • IBM 88772ru | User Guide - Page 25
    Chapter 2. Installing optional devices This chapter provides detailed instructions for installing optional hardware devices in the server. Server components The following information panel Hot-swap hard disk drive Hard disk drive filler panel © Copyright IBM Corp. 2006 Power supply filler 13
  • IBM 88772ru | User Guide - Page 26
    I/O board internal connectors The following illustration shows the internal connectors on the I/O board. IDE signal Operator panel IDE power SAS signal SAS power Front USB Fans 2 and 3 1 2 3 4 14 IBM System x3755 Type 8877: User's Guide
  • IBM 88772ru | User Guide - Page 27
    I/O board internal option connectors The following illustration shows the internal option connectors on the I/O board. PCI-E x8 PCI-E x4 PCI-X 64 bit/100 MHz PCI-X 64 bit/100 MHz PCI-E x8 PCI-E x16 HyperTransport (HTX) Remote Supervisor Adapter II SlimLine Power supply 2 ServeRAID SAS Fan 5 Fan
  • IBM 88772ru | User Guide - Page 28
    the jumper to pins 2 and 3 to prevent a Wake on LAN packet from waking the system when the system is in the powered-off state. 16 IBM System x3755 Type 8877: User's Guide
  • IBM 88772ru | User Guide - Page 29
    I/O board LEDs The following illustration shows the LEDs on the I/O board. Slot 3 error LED Slot 4 error LED Slot 5 error LED Slot 6 error LED Slot 2 error LED Slot 1 error LED HTX error LED I/O board error LED RAID controller error LED RAID DIMM error LED RAID battery error LED BMC heartbeat LED
  • IBM 88772ru | User Guide - Page 30
    DIMM 6 error LED DIMM 8 error LED Light path diagnostics button power LED Light path diagnostics button Microprocessor/memory card error LED Microprocessor error LED 18 IBM System x3755 Type 8877: User's Guide
  • IBM 88772ru | User Guide - Page 31
    SAS-backplane connectors The following illustration shows the connectors on the SAS backplane. SAS hard disk drive connectors SAS signal SAS power Chapter 2. Installing optional devices 19
  • IBM 88772ru | User Guide - Page 32
    is not working correctly, see the Installation Guide for diagnostic information. v When you install server, go to http://www.ibm.com/servers/eserver/support/xseries/index.html, select System x3755 points on hot-swap components.) See the instructions for removing or installing a specific hot-swap
  • IBM 88772ru | User Guide - Page 33
    list of supported optional devices for the server, see http://www.ibm.com/ servers power supply installed. v You have followed the cabling instructions that come with optional adapters. v You have replaced of data. To avoid this potential problem, always use an electrostatic-discharge wrist strap
  • IBM 88772ru | User Guide - Page 34
    is otherwise working correctly. If the server is not working correctly, see the Problem Determination and Service Guide for diagnostic information. To remove the cover, complete the following steps: 1. Read of the rack until the slide rails lock into place. 22 IBM System x3755 Type 8877: User's Guide
  • IBM 88772ru | User Guide - Page 35
    or replace a hot-swap power supply in the server: v The server comes with a minimum of one power supply and supports up to two power supplies. v One power supply at 220 V ac can support a fully configured server. A second power supply at 220 V ac supplies redundancy. v One power supply at 110 V ac
  • IBM 88772ru | User Guide - Page 36
    that has this label attached. There are no serviceable parts inside these components. If you suspect a problem with one of these parts, contact a service technician. Locking handle (open) Power supply 2 server cover. See "Removing the cover" on page 22. 24 IBM System x3755 Type 8877: User's Guide
  • IBM 88772ru | User Guide - Page 37
    install or replace a hot-swap fan. Attention: To ensure proper server operation, if a fan fails, replace it as soon as possible. v The server supports a maximum of six hot-swap fans. v If you install or remove a hot-swap fan, observe the following precautions. Statement 27: CAUTION: Hazardous moving
  • IBM 88772ru | User Guide - Page 38
    server. 4. Open the fan-locking handle on the replacement fan. 5. Lower the fan into the socket, and close the handle to the locked position. 26 IBM System x3755 Type 8877: User's Guide
  • IBM 88772ru | User Guide - Page 39
    notes describe the types of adapters that the server supports and other information that you must consider when you install an adapter: v Locate the documentation that comes with the adapter and follow those instructions in addition to the instructions in this section. If you must change the switch
  • IBM 88772ru | User Guide - Page 40
    Adapter retention latch 4. See the documentation that comes with the adapter for instructions for setting jumpers or switches and for cabling. Note: Route adapter cables board. f. If necessary remove the adapter guide before you install a full-length adapter. 28 IBM System x3755 Type 8877: User
  • IBM 88772ru | User Guide - Page 41
    Adapter guide Attention: When you install an adapter, avoid touching the components and gold-edge connectors on the adapter. Make sure that the adapter is correctly seated
  • IBM 88772ru | User Guide - Page 42
    Remote Supervisor Adapter II SlimLine An optional IBM Remote Supervisor Adapter II SlimLine can be installed only the adapter. 4. Press the assembly firmly into the connector and under the retention latch on the guide. If you have other devices to install or remove, do so now; otherwise, go to "Completing
  • IBM 88772ru | User Guide - Page 43
    Installing the ServeRAID-8k SAS controller An optional ServeRAID-8k SAS controller can be installed only in its dedicated connector on the I/O board. The server comes with a ServeRAID-8k-l SAS controller installed. The ServeRAID-8k SAS controller is not cabled to the server and no rerouting of the
  • IBM 88772ru | User Guide - Page 44
    supports and other information that you must consider when you install a hard disk drive: v The server supports a list of supported optional devices for the server, see http://www.ibm.com/ servers/ IBM ServeRAID Support CD for additional information about RAID operation and complete instructions
  • IBM 88772ru | User Guide - Page 45
    the disk arrays before you install the operating system. See the ServeRAID documentation on the IBM ServeRAID Support CD for additional information about RAID operation and complete instructions for using ServeRAID Manager. Installing memory modules The following notes describe the types of dual
  • IBM 88772ru | User Guide - Page 46
    microprocessor/memory card do not support Chipkill memory, the microprocessor/memory card does not support Chipkill memory. v The server supports online-spare memory. This following illustration shows the DIMM connectors on the microprocessor/memory card. 34 IBM System x3755 Type 8877: User's Guide
  • IBM 88772ru | User Guide - Page 47
    DIMM 1 DIMM 3 DIMM 5 DIMM 7 DIMM 2 DIMM 4 DIMM 6 DIMM 8 To install a DIMM, complete the following steps: 1. Read the safety information that begins on page v and "Installation guidelines" on page 20. 2. Turn off the server and peripheral devices, and disconnect the power cords and all external
  • IBM 88772ru | User Guide - Page 48
    breaking the DIMM retaining clips or damaging the DIMM connectors, open and close the clips gently. 6. Lift open the microprocessor/memory card air baffle. 36 IBM System x3755 Type 8877: User's Guide
  • IBM 88772ru | User Guide - Page 49
    Air baffle 7. Open the retaining clip on each end of the DIMM connector. 8. Touch the static-protective package that contains the DIMM to any unpainted metal surface on the outside of the server; then, remove the DIMM from the package. 9. Turn the DIMM so that the DIMM keys align correctly with the
  • IBM 88772ru | User Guide - Page 50
    the I/O board. b. Align the microprocessor/memory card with the guides. c. Press the microprocessor/memory card into the connectors and close .ibm.com/servers/eserver/support/xseries/index.html. v Obtain an SMP-capable operating system. For a list of supported operating systems, see http://www.ibm.
  • IBM 88772ru | User Guide - Page 51
    and slot 2 None Slot 1, slot 2, and slot 3 Slot 4 Slot 1, slot 2, slot 3, and slot 4 None v All 6 fans must be installed to support some microprocessor/memory card configurations. See Table 6 for the fan requirements. Table 6. Fan requirements Slots populated with microprocessor/ memory cards
  • IBM 88772ru | User Guide - Page 52
    align with the connectors on the I/O board. b. Align the microprocessor/memory card with the guides. c. Press the microprocessor/memory card into the connectors and close the retention levers. Slide the cover-release latch to lock the cover in place. 40 IBM System x3755 Type 8877: User's Guide
  • IBM 88772ru | User Guide - Page 53
    Top cover Cover-release latch 2. Install the server in a rack. See the Rack Installation Instructions that come with the server for complete rack installation and removal instructions. Attention: v Install the server only in a rack cabinet with perforated doors. v Do not leave open spaces above or
  • IBM 88772ru | User Guide - Page 54
    cables from the server. See the documentation that comes with optional devices for additional cabling instructions. It might be easier for you to route cables before you install certain devices. LED System-error LED Release latch USB connectors 42 IBM System x3755 Type 8877: User's Guide
  • IBM 88772ru | User Guide - Page 55
    (SMP) server. You might have to upgrade the operating system to support SMP. For more information, see "Using the ServerGuide Setup and Installation CD the server remotely, see the Remote Supervisor Adapter II SlimLine User's Guide, which comes with the adapter, for information about setting up,
  • IBM 88772ru | User Guide - Page 56
    44 IBM System x3755 Type 8877: User's Guide
  • IBM 88772ru | User Guide - Page 57
    ServeRAID Configuration Utility program" on page 66. - ServeRAID Manager ServeRAID Manager is available as a stand-alone program and as an IBM Director extension. Use ServeRAID Manager to define and configure your disk-array subsystem before you install the operating system. For information about
  • IBM 88772ru | User Guide - Page 58
    Change interrupt request (IRQ) settings v Enable USB legacy keyboard and mouse support v Resolve configuration conflicts Starting the Configuration/Setup Utility program To start the that are stored in electrically erasable programmable ROM (EEPROM). 46 IBM System x3755 Type 8877: User's Guide
  • IBM 88772ru | User Guide - Page 59
    - System Card Data Select this choice to view vital product data (VPD) for some server components. v Devices and I/O Ports Select this choice to view or change assignments for devices and input/output (I/O) ports. Select this choice to enable or disable integrated SAS and Ethernet controllers and
  • IBM 88772ru | User Guide - Page 60
    malfunction if these settings are incorrectly configured. Follow the instructions on the screen carefully. This choice is on the choice to manually enable a pair of memory connectors, memory node interleaving, and Chipkill memory (if it is supported). If a 48 IBM System x3755 Type 8877: User's Guide
  • IBM 88772ru | User Guide - Page 61
    system event/error log contains all event and error messages that have been generated during POST by the systems-management interface handler and the service processor. v Save Settings Select this choice to save the changes that you have made in the settings. v Restore Settings Select this choice to
  • IBM 88772ru | User Guide - Page 62
    battery from the server and then reinstall it. For instructions for removing the battery, see ″Replacing the battery″ in the Problem Determination and Service Guide. v Change the position of the power-on password boot recovery, and Wake on LAN jumpers. 50 IBM System x3755 Type 8877: User's Guide
  • IBM 88772ru | User Guide - Page 63
    up to seven characters (A-Z, a-z, and 0-9) for the password. The Administrator Password choice is on the Configuration/Setup Utility menu only if an optional IBM Remote Supervisor Adapter II SlimLine is installed. Attention: If you set an administrator password and then forget it, there is no way to
  • IBM 88772ru | User Guide - Page 64
    and Installation CD, you do not need setup diskettes. You can use the CD to configure any supported IBM server model. The setup program provides a list of tasks that are required to set up the . v View the overview to learn about ServerGuide features. 52 IBM System x3755 Type 8877: User's Guide
  • IBM 88772ru | User Guide - Page 65
    information about the server model, service processor, hard disk drive controllers ibm.com/servers/eserver/support/xseries/index.html. 2. From the Hardware list, select System x3755 and click Go. 3. Click the Install and use tab. 4. Click Product documentation. 5. Select the installation instructions
  • IBM 88772ru | User Guide - Page 66
    www.ibm.com/servers/eserver/support/xseries/ service-processor environmental monitoring functions. If an environmental condition exceeds a threshold or if a system component fails, the baseboard management controller lights LEDs to help you diagnose the problem IBM System x3755 Type 8877: User's Guide
  • IBM 88772ru | User Guide - Page 67
    steps. 1. Update the BIOS code: a. Download the latest version of the BIOS code from http://www.ibm.com/ servers/eserver/support/xseries/index.html. b. Update the BIOS code, following the instructions that come with the update file that you downloaded. 2. Configure the BIOS settings: a. Restart the
  • IBM 88772ru | User Guide - Page 68
    the serial console. See the documentation for your specific Linux operating-system type for information and instructions. Use one of the following procedures to enable SOL sessions for your Linux operating system. You 12smp.img read-only root=/dev/hda6 56 IBM System x3755 Type 8877: User's Guide
  • IBM 88772ru | User Guide - Page 69
    append="console=tty1 console=ttyS0,19200n8 " The following examples show the original content of the /etc/lilo.conf file and the content of this file after modification. Original /etc/lilo.conf contents prompt timeout=50 default=linux boot=/dev/hda map=/boot/map install=/boot/boot.b message=/boot/
  • IBM 88772ru | User Guide - Page 70
    with the OS boot via SOL title Red Hat Linux (2.4.9-e.12smp) SOL Interactive root (hd0,0) kernel /vmlinuz-2.4.9-e.12smp ro root=/dev/hda6 console=tty1 58 IBM System x3755 Type 8877: User's Guide
  • IBM 88772ru | User Guide - Page 71
    console=ttyS0,19200 initrd /initrd-2.4.9-e.12smp.img Note: The entry that begins with kernel /vmlinuz is shown with a line break after console=tty1. In your file, the entire entry must all be on one line. The following examples show the original content of the /boot/grub/grub.conf file and the
  • IBM 88772ru | User Guide - Page 72
    /securetty file to enable a user to log in as the root user through the SOL console: ttyS0 3. Modify the /boot/grub/menu.lst file: 60 IBM System x3755 Type 8877: User's Guide
  • IBM 88772ru | User Guide - Page 73
    a. Comment out the gfxmenu line by adding a # in front of the word gfxmenu. b. Add the following line before the first title line: # This will allow you to only Monitor the OS boot via SOL c. Append the following text to the first title line: SOL Monitor d. Append the following text to the kernel
  • IBM 88772ru | User Guide - Page 74
    (0)partition(1)\WINDOWS Boot Entries Boot entry ID: 1 OS Friendly Name: Windows Server 2003, Standard Path: multi(0)disk(0)rdisk(0)partition(1)\WINDOWS OS Load Options: /fastdetect 62 IBM System x3755 Type 8877: User's Guide
  • IBM 88772ru | User Guide - Page 75
    following steps to install the OSA SMBridge management utility program on a server running a Windows operating system: 1. Go to http://www.ibm.com/servers/eserver/support/xseries/index.html, download the utility program, and create the OSA BMC Management Utility CD. 2. Insert the OSA BMC Management
  • IBM 88772ru | User Guide - Page 76
    /servers/eserver/support/ xseries/index.html; then, copy the bmc_cfg.exe file to a configuration utility diskette on a USB-connected diskette drive. To start the baseboard management controller configuration utility program, complete the following steps: 64 IBM System x3755 Type 8877: User's Guide
  • IBM 88772ru | User Guide - Page 77
    line prompt, type bmc_cfg and press Enter. 3. Follow the instructions on the screen. Using the baseboard management controller firmware update utility available from http://www.ibm.com/servers/eserver/support/xseries/ index.html. If you have installed the OSA device driver and IBM Mapping Layer, you
  • IBM 88772ru | User Guide - Page 78
    IBM ServeRAID Support CD that comes with the ServeRAID option. Starting the IBM ServeRAID Configuration Utility program To start the IBM ServeRAID follow the instructions on the screen. IBM ServeRAID Configuration Utility menu choices The following choices are on the IBM ServeRAID Configuration
  • IBM 88772ru | User Guide - Page 79
    for the array build method, select Quick Init. 9. Follow the instructions on the screen to complete the configuration; then, select Done to Esc. Using ServeRAID Manager Use ServeRAID Manager, which is on the IBM ServeRAID Support CD, to perform the following tasks: v Configure a redundant array
  • IBM 88772ru | User Guide - Page 80
    technology and instructions for using ServeRAID Manager to configure the integrated SCSI controller with RAID capabilities, see the ServeRAID documentation on the IBM ServeRAID Support CD. Additional the hot-spare drive, and click the icon to add the drive. 68 IBM System x3755 Type 8877: User's Guide
  • IBM 88772ru | User Guide - Page 81
    this section, see the IBM Remote Supervisor Adapter II User's Guide for information about how browsers are supported: - Microsoft Internet Explorer version 5.5 or later with the latest Service Pack to download software and firmware from the IBM Support Web site during the installation process. The
  • IBM 88772ru | User Guide - Page 82
    about network configuration, see the Remote Supervisor Adapter II Installation Guide. To cable the Remote Supervisor Adapter II SlimLine, complete service package installation kit. The kit contains the following files: v Software and firmware installation instructions v BIOS code update with support
  • IBM 88772ru | User Guide - Page 83
    Completing the setup See the IBM Remote Supervisor Adapter II User's Guide on the IBM System x Documentation CD for instructions for completing the configuration, including the following procedures: v Configuring the Ethernet ports v Defining login IDs and passwords v Selecting the events that will
  • IBM 88772ru | User Guide - Page 84
    72 IBM System x3755 Type 8877: User's Guide
  • IBM 88772ru | User Guide - Page 85
    in the drop-down list, follow the instructions on the Web page to download the latest version. 2. Install the IBM Director program. 3. Download and install any applicable updates or interim fixes for the server: a. Go to http://www.ibm.com/servers/eserver/support/xseries/index.html. b. From the
  • IBM 88772ru | User Guide - Page 86
    74 IBM System x3755 Type 8877: User's Guide
  • IBM 88772ru | User Guide - Page 87
    right may be used instead. However, it is the user's responsibility to evaluate and verify the operation of any non-IBM product, program, or service. IBM may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not
  • IBM 88772ru | User Guide - Page 88
    and other countries. Other company, product, or service names may be trademarks or service marks of others. Important notes Processor speeds indicate the hard disk drive bays with the largest currently supported drives available from IBM. Maximum memory may require replacement of the standard memory
  • IBM 88772ru | User Guide - Page 89
    no representations or warranties with respect to non-IBM products. Support (if any) for the non-IBM products is provided by the third party, not IBM. Some software may differ from its retail version (if available), and may not include user manuals or all program functionality. Product recycling and
  • IBM 88772ru | User Guide - Page 90
    EEE on the environment and human health due to the potential presence of hazardous substances in EEE. For proper collection and treatment, contact your local IBM representative. 78 IBM System x3755 Type 8877: User's Guide
  • IBM 88772ru | User Guide - Page 91
    Index A Active Memory 4 Active PCI-X 27 adapter hypertransport 27 installing 27 IBM Remote Supervisor Adapter II SlimLine 30 ServeRAID-8k 31 non-hot-plug 27 PCI bay 33 firmware code, updating 64 G Gigabit Ethernet connector 10 H handling static-sensitive devices 21 © Copyright IBM Corp. 2006 79
  • IBM 88772ru | User Guide - Page 92
    8k 31 integrated baseboard management controller utility programs 64 network support 4 integrated functions 3 J jumpers boot recovery 16 power- on LAN 16 16, 50 K keyboard connector 10 80 IBM System x3755 Type 8877: User's Guide L LED I/O board, illustration 17 microprocessor/memory card,
  • IBM 88772ru | User Guide - Page 93
    52 NOS installation 53 Setup and Installation CD 4, 45 using 51 serviceability 6 setup with ServerGuide 52 size 3 slots 3 SMP 5 specifications Setup program, using 45 IBM ServeRAID Configuration 66 OSA SMBridge management utility program 65 V video connector 10 W Web site IBM 2 ServerGuide 52 weight
  • IBM 88772ru | User Guide - Page 94
    82 IBM System x3755 Type 8877: User's Guide
  • IBM 88772ru | User Guide - Page 95
  • IBM 88772ru | User Guide - Page 96
    Part Number: 31R1545 Printed in USA (1P) P/N: 31R1545
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

IBM
System
x3755
Type
8877
User’s
Guide
±²³