Idle, E3h/97h
View all IBM DTTA-351010 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 118 highlights
12.6 Idle (E3h/97h) Command Block Output Registers Register 76543210 Data Feature Sector Count V V V V V V V V Sector Number Cylinder Low Cylinder High Device/Head 1 1D Command 11100011 Command Block Input Registers Register 76543210 Data Error ...See Below... Sector Count Sector Number Cylinder Low Cylinder High Device/Head Status ...See Below... Error Register 76543210 CRC UNC 0 IDN 0 ABT T0N AMN 00000V00 Status Register 76543210 BSY RDY DF DSC DRQ COR IDX ERR 0V0V 0 V Figure 84. Idle Command (E3h/97h) The Idle command causes the device to enter Idle mode immediately, and set auto power down timeout parameter(standby timer). And then the timer starts counting down. When the Idle mode is entered, the device is spun up to operating speed. If the device is already spinning, the spin up sequence is not executed. During Idle mode the device is spinning and ready to respond to host commands immediately. Output Parameters To The Device Sector Count Timeout Parameter. If zero, then the automatic power down sequence is disabled. If non-zero,then the automatic power down sequence is enabled,and the timeout interval is shown blow: Value ----------- 0 1 - 240 241 - 251 252 253 254 255 Timeout Timer disabled Value * 5 seconds (Value-240) * 30 minutes 21 minutes 8 hours 21 minutes 10 seconds 21 minutes 15 seconds 110 OEM Specifications for DTTA-3xxxxx