Page 51 highlights
6.4 Environment Figure 35. Environmental Condition Operating Conditions Temperature Relative Humidity Maximum Wet Bulb Temperature Maximum Temperature Gradient Altitude 5 to 55˚C (See note) 8 to 90 % R H non-condensing 29.4˚C non-condensing 15˚ C / Hour − 300 to 3048 m Non-Operating Conditions Temperature Relative Humidity Maximum Wet Bulb Temperature Maximum Temperature Gradient Altitude Note: − 40 to 65˚ C 5 to 95 % R H non-condensing 35˚ C non-condensing 15˚ C / Hour − 300 to 12,000 m The system has to provide sufficient ventilation to maintain a surface temperature below 60˚ C at the center of the top cover of the drive. Non-operating condition should not continue beyond one year. Specification 43
6.4
Environment
Figure 35. Environmental Condition
Operating Conditions
Temperature
5 to 55˚C (See note)
Relative Humidity
8 to 90 %RH non-condensing
Maximum Wet Bulb Temperature
29.4˚C non-condensing
Maximum Temperature Gradient
15˚C / Hour
Altitude
-
300 to 3048 m
Non-Operating Conditions
Temperature
-
40 to 65˚C
Relative Humidity
5 to 95 %RH non-condensing
Maximum Wet Bulb Temperature
35˚C non-condensing
Maximum Temperature Gradient
15˚C / Hour
Altitude
-
300 to 12,000 m
Note:
The system has to provide sufficient ventilation to maintain a surface temperature below 60˚C at the
center of the top cover of the drive.
Non-operating condition should not continue beyond one year.
Specification