Icom IC-M802 Instruction Manual - Page 70
Connector information continued
![]() |
View all Icom IC-M802 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 70 highlights
13 CONFECTION AND INSTALLATION I Connector information (continued) AF/MOD 5 1 9 6 Pin Pin name Description 1 MOD+ Modulation input from an external terminal unit. 2 MOD- Coaxial ground for NMD+. 3 GND Ground for digital equipment. 4 NAF+ AF detector output for an external terminal unit. 5 NAF- Coaxial ground for NAF+. 6 GND Ground for digital equipment. 7 NC No connection. 8 SEND Transmits when grounded. 9 GND Ground for digital equipment. Specification Input impedance : 600 Ω Input level : Approx. 0.77 V rms. Output impedance: 600 Ω Output level : 0.25-2.5 mV rms Output level Input level : -0.5 to 0.8 V : Less than 20 mA REMOTE 5 1 9 6 Pin Pin name Description 1 DCD Input terminal for carrier detection. 2 RXD Input terminal for receive data. ("RS-232C" selection for REMOTE IF. (p. 52)) NMEA-OUT NMEA0183 ver. 3.01 data output. ("NMEA" selection for REMOTE IF. (p. 52)) 3 TXD Outputs transmit data. ("RS-232C" selection for REMOTE IF. (p. 52)) NMEA-IN NMEA0183 ver. 3.01 data input. ("NMEA" selection for REMOTE IF. (p. 52)) 4 DTR Outputs data terminal ready signal. 5 GND Connected to the ground. 6 DSR Input terminal for data-set-ready signal. 7 RTS Outputs request-to-send data. 8 CTS Input terminal for clear-to-send data. 9 NC No connection. GPS q w Pin Pin name Description 1 NMEA + NMEA0183 ver 3.01 data input +. 2 NMEA _ Ground for NMEA data. 62