Intel S3420GPLC Product Specification - Page 127

Intel® Server Board S3420GP TPS, Appendix B: Integrated BMC Sensor Tables, Revision 2.4, Intel order

Page 127 highlights

Intel® Server Board S3420GP TPS Appendix B: Integrated BMC Sensor Tables Sensor Name3 IPMI Watchdog Physical Scrty FP Interrupt (NMI) System Event Log System Event (System Event) BB +1.05 PCH Table 73. Integrated BMC Core Sensors Sensor # Platform Sensor Type Applicability 03h All Watchdog 2 23h 04h Chassis Intrusion is chassisspecific Physical Security 05h Critical 05h All Interrupt 13h Event 07h All Logging Disabled 10h System 08h All Event 12h Event / Reading Type Sensor Specific 6Fh Sensor Specific 6Fh Sensor Specific 6Fh Sensor Specific 6Fh Sensor Specific 6Fh Event Offset Triggers 00 - Timer expired, status only 01 - Hard reset 02 - Power down 03 - Power cycle 08 - Timer interrupt 00 - Chassis intrusion 04 - LAN least lost 00 - Front panel NMI/diagnostic interrupt Contrib. To System Status OK OK Degraded OK 02 - Log area reset/cleared OK 04 - PEF OK action Assert / De- assert Readable Value / Offsets Event Data Rearm Standby As - Trig Offset A X X As and De - Trig Offset A As - Trig Offset A - As - Trig Offset A X As - Trig Offset A,I X nc = 10h All Voltage 02h Threshold 01h [u,l] [c,nc] Degraded c = Non- As and De Analog R, T A - fatal Revision 2.4 115 Intel order number E65697-010

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144

Intel® Server Board S3420GP TPS
Appendix B: Integrated BMC Sensor Tables
Revision 2.4
Intel order number E65697-010
115
Table 73. Integrated BMC Core Sensors
Sensor Name
3
Sensor #
Platform
Applicability
Sensor Type
Event /
Reading
Type
Event Offset
Triggers
Contrib. To
System
Status
Assert /
De-
assert
Readable
Value /
Offsets
Event
Data
Rearm
Stand-
by
IPMI Watchdog
03h
All
Watchdog 2
23h
Sensor
Specific
6Fh
00 - Timer
expired, status
only
01 - Hard reset
02 - Power
down
03 - Power
cycle
08 - Timer
interrupt
OK
As
Trig Offset
A
X
Physical Scrty
04h
Chassis
Intrusion is
chassis-
specific
Physical
Security
05h
Sensor
Specific
6Fh
00 - Chassis
intrusion
OK
As and
De
Trig Offset
A
X
04 - LAN least
lost
Degraded
FP Interrupt
(NMI)
05h
All
Critical
Interrupt
13h
Sensor
Specific
6Fh
00 - Front
panel
NMI/diagnostic
interrupt
OK
As
Trig Offset
A
System Event Log
07h
All
Event
Logging
Disabled
10h
Sensor
Specific
6Fh
02 - Log area
reset/cleared
OK
As
Trig Offset
A
X
System Event
(System Event)
08h
All
System
Event
12h
Sensor
Specific
6Fh
04 – PEF
action
OK
As
-
Trig Offset
A,I
X
BB +1.05 PCH
10h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A