Intel S3420GPLC Product Specification - Page 55

Setup Utility - Fan controller Manual Display, Table 14. Setup Utility - Hardware Monitor

Page 55 highlights

Intel® Server Board S3420GP TPS Server Management Capability for Intel® Server Board S3420GPV Advanc Secu rit Ma in  ed y Hardware monitor S erv er Mana ge ment Boot Options Boot Manager  Real-time Temperature and Voltage Status Fan Controller M anu al CPU Fan Hysteresis Default Fan PW M [2 Degree Celsius/3 Degree Celsius/4 Degree Celsius [ 40%/60 %/80%/ 100%] System Fan Hysteresis Default Fan PWM [2 Degree Celsius/3 Degree Celsius/4 Degree Celsius [ 40%/60 %/80%/ 100%] Auxiliary Fan 1 Hysteresis Default Fan PWM [2 Degree Celsius/3 Degree Celsius/4 Degree Celsius [ 40%/60 %/80%/ 100%] Auxiliary Fan 2 Hysteresis Default Fan PWM [2 Degree Celsius/3 Degree Celsius/4 Degree Celsius [ 40%/60 %/80%/ 100%] Figure 16. Setup Utility - Fan controller (Manual) Display Table 14. Setup Utility - Hardware Monitor Screen Fields Setup Item Voltage and Temperature Status CPU Fan Controller Options Auto Manual Help Text display monitored voltage, current Fan speed PWM and temperature CPU temperature control policy Auto - Fan speed control setting by default Manual - user adjust Fan speed control setting value manually Comments Revision 2.4 43 Intel order number E65697-010

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144

Intel® Server Board S3420GP TPS
Server Management Capability for Intel® Server Board S3420GPV
Revision 2.4
Intel order number E65697-010
43
Main
Advanc
ed
Secu rit
y
Server
Management
Boot
Options
Boot Manager
Hardware monitor
Real-time Temperature and Voltage Status
Fan Controller
Manual
CPU Fan
Hysteresis
Default Fan PWM
[2 Degree Celsius/
3 Degree Celsius
/4 Degree Celsius
[40%/60%/80%/
100%
]
System Fan
Hysteresis
Default Fan PWM
[
2 Degree Celsius
/3 Degree Celsius/4 Degree Celsius
[40%/60%/80%/
100%
]
Auxiliary Fan 1
Hysteresis
Default Fan PWM
[
2 Degree Celsius
/3 Degree Celsius/4 Degree Celsius
[40%/60%/80%/
100%
]
Auxiliary Fan 2
Hysteresis
Default Fan PWM
[2 Degree Celsius/
3 Degree Celsius
/4 Degree Celsius
[40%/60%/80%/
100%
]
Figure 16. Setup Utility — Fan controller (Manual) Display
Table 14. Setup Utility — Hardware Monitor Screen Fields
Setup Item
Options
Help Text
Comments
Voltage and
Temperature Status
display monitored voltage, current
Fan speed PWM and temperature
CPU Fan Controller
Auto
Manual
CPU temperature control policy
Auto - Fan speed control setting by
default
Manual - user adjust Fan speed
control setting value manually