PERFORMANCE DATA SHEET Base Grille Water Filtration System Model T1 KB1/T1 RFKB1 Capacity 100 Gallons (379 Liters) System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of Chlorine Taste and Odor, Particulate Class I*; and against NSF/ANSI Standard 53 for the reduction of Lead, Mercury, Atrazine, Benzene, Toxaphene, O-Dichlorobenzene, Cysts, Turbidity, Asbestos, Lindane, Tetrachloroethylene, Endrin, Alachlor, Chlorobenzene, Ethylbenzene, TTHM, MTBE and VOC. This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53. Substance Reduction NSF Reduction Average Aesthetic Effects Requirements Influent Influent Challenge Concentration Maximum Effluent Average Effluent Minimum % Average % Reduction Reduction Chlorine Taste/Odor Particulate Class I* Contaminant Reduction Lead: @ pH 6.5 Lead: @ pH 8.5 Mercury: @ pH 6.5 Mercury: @ pH 8.5 Benzene O-Dichlorobenzene Toxaphene Atrazine Asbestos 50% reduction 85% reduction NSF Reduction Requirements 0.010 mg/L 0.010 mg/L 0.002 mg/L 0.002 mg/L 0.005 mg/L 0.6 mg/L 0.003 mg/L 0.003 mg/L 99% 2.0 mg/L 3533333#/mL Average Influent 150 ug/L 157 ug/L 0.0058 mg/L 0.0057 mg/L 15 ug/L 1750 ug/L 15 ug/L 10 ug/L 101 MFL 2.0 mg/L + 10% At east 10,000 part c es/mL Influent Challenge Concentration 0.08 mg/L ** 22000 #/mL Maximum Effluent 0.15 mg/L + 10% 0.15 mg/L _+10% 1.0 ug/L 2.0 ug/L 0.006 mg/L + 10% 0.006 mg/L _+10% 0.0002 mg/L 0.0002 mg/L 0.015 mg/L _+10% 0.5 ug/L 1.8 _+10% 1.0 ug/L 0.015 _+10% 1.0 ug/L 0.009 mg/L _+10% 107to 108fibers/U t 2 ug/L 0.17 MFL 2.0 mg/L 11567 #/mL Average Effluent 1 ug/L 1.08 ug/L 0.0002 mg/L 0.0002 mg/L 0.5 ug/L 1.0 ug/L 1.0 ug/L 2 ug/L 0.17 MFL 95.93 99.38 Minimum % Reduction 99.33 98.72 96.53 96.5 96.67 99.94 93.33 80.8 99.83 97.36 99.67 Average % Reduction 99.33 99.31 96.53 96.5 96.67 99.94 93.33 80.8 99.83 Live Cysts _ Turbidity Alachlor Endrin Ethylbenzene Lindane Chlorobenzene Tetrachloroethylene TTHM MTBE V©C >99.95% 0.5 NTU 0.002 mg/L 0.002 mg/L 0.7 mg/L 0.002 mg/L 0.6 mg/L 0.005 mg/L 0.080 mg/L 0.005 mg/L 0.015 mg/L 120,000/L 11.4 NTU 41.3 ug/L 5.9 ug/L 1867 ug/L 1.9 ug/L 2.0 ug/L 14.2 ug/L 465 ug/L 14 ug/L 0.3520 mg/L 50,000/L min. 11 _+1 NTU 0.04 _+10% 0.006 _+10% 2.1 _+10% 0.002 _+10% 2.0 _+10% 0.015 _+10% 0.45 _+20% 0.015 _+20% 0.300 _+10% 8/U 0.41 NTU 0.2 ug/L 0.5 ug/L 0.70 ug/L 0.02 ug/L 0.0005 ug/L 0.5 ug/L 1.0 ug/L 0.70 ug/L 0.0060 mg/L 1/U 0.24 NTU 0.2 ug/L 0.3 ug/L 0.0588 ug/L 0.02 ug/L 0.0005 ug/L 0.5 ug/L 0.5 ug/L 0.52 ug/L 0.0008 mg/L 99.99 96.4 99.52 91.5 99.96 98.93 99.98 96.47 99.78 94.94 98.4 >99.99 97.89 99.52 95.47 100 98.93 99.98 96.47 99.88 96.27 99.78 Test Parameters: pH = 7.5 _+0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 100 gallons (379 liters). • It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised. • Model TIKBI" The filter monitor system measures the amount of water that passes through the filter and alerts you to replace the filter. • Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts. • Refer to the front cover or "Accessories" section for the Manufacturer's name, address and telephone number. Style 1 - When the filter indicator reads 10%, order a new filter. When the filter indicator reads 0%, it is recommended that you replace the filter. • Refer to the "Warranty" section for the Manufacturer's limited warranty. Style 2 - When the filter indicator light changes from green to yellow, order a new filter. When the filter indicator light changes from yellow to red, it is recommended that you replace the filter. Application Water Supply Guidelines/Water Supply Parameters City or Well Use replacement cartridge T1 RFKB1, part #9030. In Canada, use replacement cartridge T1 RFKB1, part #9030B. 2008 suggested retail price of $41.99 U.S.A./S51.99 Canada. Prices are subject to change without notice. Water Pressure Water Temperature Service Flow Rate 30 - 120 psi (207 - 827 kPa) 33 ° - 100°F (0.6 ° - 37.8°C) 0.5 gpm (1.9 L/min) @ 60 psi • These contaminants are not necessarily in your water supply. While testing was performed under standard laboratory conditions, actual performance may vary. • The product is for cold water use only. *Class I particle size: >0.5 to