Performance Data Sheet
UPC - 883049131900
View all Kenmore 5478 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 26 highlights
PERFORMANCE DATA SHEET Base Grille Water Filtration System Model TIKB1/TIRFKB1 Capacity 100 Gallons (379 Liters) System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of Chlorine Taste and Odor, Particulate Class I*; and against NSF/ANSI Standard 53 for the reduction of Lead, Mercury, Atrazine, Benzene, Toxaphene, O-Dichlorobenzene, Cysts, Turbidity, Asbestos, Lindane, Tetrachloroethylene, Endrin, Alachlor, Chlorobenzene, Ethylbenzene, TTHM, MTBE and VOC. This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSl Standards 42 and 53. Substance Reduction NSF Reduction Average Aesthetic Effects Requirements Influent Influent Challenge Concentration Maximum Effluent Average Effluent Minimum % Average % Reduction Reduction Chlorine Taste/Odor Particulate Class I* Contaminant Reduction Lead: @ pH 6.5 Lead: @ pH 8.5 Mercury: @ pH 6.5 Mercury: @ pH 8.5 Benzene O-Dichlorobenzene Toxaphene Atrazine Asbestos 50% reduction 85% reduction NSF Reduction Requirements 0.010 mg/L 0.010 mg/L 0.002 mg/L 0.002 mg/L 0.005 mg/L 0.6 mg/L 0.003 mg/L 0.003 mg/L 99% 2.0 mg/L 3533333#/mL Average Influent 150 ug/L 157 ug/L 0.0058 mg/L 0.0057 mg/L 15 ug/L 1750 ug/L 15 ug/L 10 ug/L 101 MFL 2.0 mg/L + 10% At least 10,000 part c es/mL Influent Challenge Concentration 0.15 mg/L + 10% 0.15 mg/L _+10% 0.006 mg/L + 10% 0.006 mg/L _+10% 0.015 mg/L _+10% 1.8 _+10% 0.015 _+10% 0.009 mg/L _+10% 107to 108fibers/L tt 0.08 mg/L ** 22000 #/mL Maximum Effluent 1.0 ug/L 2.0 ug/L 0.0002 mg/L 0.0002 mg/L 0.5 ug/L 1.0 ug/L 1.0 ug/L 2 ug/L 0.17 MFL 2.0 mg/L 11567 #/mL Average Effluent 1 ug/L 1.08 ug/L 0.0002 mg/L 0.0002 mg/L 0.5 ug/L 1.0 ug/L 1.0 ug/L 2 ug/L 0.17 MFL 95.93 99.38 Minimum % Reduction 99.33 98.72 96.53 96.5 96.67 99.94 93.33 80.8 99.83 97.36 99.67 Average % Reduction 99.33 99.31 96.53 96.5 96.67 99.94 93.33 80.8 99.83 Live Cysts _ Turbidity Alachlor Endrin Ethylbenzene Lindane Chlorobenzene Tetrachloroethylene TTHM MTBE VOC >99.95% 0.5 NTU 0.002 mg/L 0.002 mg/L 0.7 mg/L 0.002 mg/L 0.6 mg/L 0.005 mg/L 0.080 mg/L 0.005 mg/L 0.015 mg/L 120,000/L 11.4 NTU 41.3 ug/L 5.9 ug/L 1867 ug/L 1.9 ug/L 2.0 ug/L 14.2 ug/L 465 ug/L 14 ug/L 0.3520 mg/L 50,000/L min. 11 _+1 NTU 0.04 _+10% 0.006 _+10% 2.1 _+10% 0.002 _+10% 2.0 _+10% 0.015 _+10% 0.45 _+20% 0.015 _+20% 0.300 _+10% 8/U 0.41 NTU 0.2 ug/L 0.5 ug/L 0.70 ug/L 0.02 ug/L 0.0005 ug/L 0.5 ug/L 1.0 ug/L 0.70 ug/L 0.0060 mg/L 1/U 0.24 NTU 0.2 ug/L 0.3 ug/L 0.0588 ug/L 0.02 ug/L 0.0005 ug/L 0.5 ug/L 0.5 ug/L 0.52 ug/L 0.0008 mg/L 99.99 96.4 99.52 91.5 99.96 98.93 99.98 96.47 99.78 94.94 98.4 >99.99 97.89 99.52 95.47 100 98.93 99.98 96.47 99.88 96.27 99.78 Test Parameters: pH = 7.5 _+0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 100 gallons (379 liters). • It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised. • Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on • Model T1KBI" The filter monitor system measures the amount of water that passes through the filter and alerts you to replace the filter. disinfected waters that may contain filterable cysts. • Refer to the "Warranty" section for the Manufacturer's name, address and telephone number. Style 1 - When the filter indicator reads 10%, order a new filter. When the indicator reads 0%, it is recommended that you replace the filter. • Refer to the "Warranty" section for the Manufacturer's limited warranty. Style 2 - When the filter indicator changes from green to yellow, order a new filter. When the indicator changes from yellow to red, it is recommended that you replace the filter. Style 3 - When the water filter status display changes from "GOOD" to "ORDER," order a new filter. When the filter indicator reads "REPLACE," it is recommended that you replace the filter. Use replacement cartridge T1 RFKB1, part #9030. 2008 suggested retail price of $59.99 U.S.A./S71.99 Prices are subject to change without notice. Canada. • These contaminants are not necessarily in your water supply. While testing was performed under standard laboratory conditions, actual performance may vary. • The product is for cold water use only. Application Water Supply Water Pressure Water Temperature Service Flow Rate Guidelines/Water Supply Parameters City or Well 30 - 120 psi (207 - 827 kPa) 33 ° - 100°F (0.6 ° - 37.8°C) 0.5 gpm (1.9 L/min) @ 60 psi *Class I particle size: >0.5 to