Kyocera FS 1100 Service Manual - Page 43
Abnormally high fuser thermistor, Broken fuser thermistor wire
View all Kyocera FS 1100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 43 highlights
2H5/2HS Code 6000 6020 6030 Contents Causes Remarks Check procedures/corrective measures Broken fuser heater lamp wire The fuser temperature does not rise after the fuser heater lamp has been turned on. Poor contact in the fuser thermistor connector terminals. Reinsert the connector (See page 1-5-16). Poor contact in the fuser heater lamp connector terminals. Reinsert the connector (See page 1-5-16). Fuser thermistor installed incorrectly. Replace the fuser unit (See page 1-5-16). Fuser thermal cut- Replace the fuser unit (See page 1-5-16). out triggered. Fuser heater lamp Replace the fuser unit (See page 1-5-16). installed incorrectly. Broken fuser Replace the fuser unit (See page 1-5-16). heater lamp wire. Abnormally high fuser thermistor temperature Fuser thermistor detects abnormally temperature. Shorted fuser ther- Replace the fuser unit (See page 1-5-16). mistor. Defective control PWB. Replace the control PWB (See page 1-519). Broken fuser thermistor wire Input from fuser thermistor is 0 (A/D value). Poor contact in the fuser thermistor connector terminals. Reinsert the connector (See page 1-5-16). Broken fuser ther- Replace the fuser unit (See page 1-5-16). mistor wire. Fuser thermistor installed incorrectly. Replace the fuser unit (See page 1-5-16). Fuser thermal cut- Replace the fuser unit (See page 1-5-16). out triggered. Fuser heater lamp Replace the fuser unit (See page 1-5-16). installed incorrectly. Broken fuser Replace the fuser unit (See page 1-5-16). heater lamp wire. 1-4-7