Page 73 highlights
7. Remove five screws and then remove the control PWB. 8. Check or replace the control PWB and refit all the removed parts. To replace the control PWB, remove the EEPROM (U300) from the old control PWB and mount it to the new control PWB. 2H5/2HS Screw Screw Control PWB Screw Screw EEPROM U300 Screw Control PWB Figure 1-5-29 1-5-21
2H5/2HS
1-5-21
7.
Remove five screws and then remove the
control PWB.
8.
Check or replace the control PWB and refit
all the removed parts.
To replace the control PWB, remove the
EEPROM (U300) from the old control PWB
and mount it to the new control PWB.
Figure 1-5-29
Screw
Screw
Screw
Screw
Screw
Control PWB
Control PWB
U300
EEPROM