The bias contact pin must be installed
View all Kyocera FS 1100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 80 highlights
2H5/2HS 18. Check or replace the high voltage PWB and refit all the removed parts. When refitting the high voltage PWB, be careful about following points. - Position the ground plate so that it is atop the high voltage PWB. - Each interface is firmly in contact with each spring. - The bias contact pin must be installed in the specified position. - The cassette pin must be inserted in the cassette pin holder. High voltage PWB OK Ground plate NG High voltage PWB 1-5-28 Spring (Transfer) Spring (separation) Spring (Main charger) Spring (Developing) Bias contact pin Cassette pin holder High voltage PWB Cassette pin Figure 1-5-39
2H5/2HS
1-5-28
18. Check or replace the high voltage PWB and
refit all the removed parts.
When refitting the high voltage PWB, be
careful about following points.
- Position the ground plate so that it is atop
the high voltage PWB.
- Each interface is firmly in contact with each
spring.
- The bias contact pin must be installed in
the specified position.
- The cassette pin must be inserted in the
cassette pin holder.
Figure 1-5-39
OK
NG
High voltage PWB
High voltage PWB
High voltage PWB
Cassette pin
Cassette pin holder
Ground plate
Bias
contact pin
Spring
(Main charger)
Spring
(separation)
Spring
(Developing)
Spring
(Transfer)