Kyocera FS 1100 Service Manual - Page 74
(2) Detaching and refitting the power source PWB, Connector, YC104, Power source PWB, assembly
View all Kyocera FS 1100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 74 highlights
2H5/2HS (2) Detaching and refitting the power source PWB Procedure 1. Remove the top cover (See page 1-5-3). 2. Remove the left cover (See page 1-5-4). 3. Remove four connectors. Connector Connector Connector Connector (YC104) 4. Remove four P tight screws, two screws and ground terminal. 5. Remove the power source PWB assembly from the high voltage PWB's connector. Ground terminal Figure 1-5-30 Screws High voltage PWB P tight screws Power source PWB assembly Connector (YC103) P tight screws Figure 1-5-31 Connector (YC201) 1-5-22
2H5/2HS
1-5-22
(2) Detaching and refitting the power source PWB
Procedure
1.
Remove the top cover (See page 1-5-3).
2.
Remove the left cover (See page 1-5-4).
3.
Remove four connectors.
Figure 1-5-30
4.
Remove four P tight screws, two screws and
ground terminal.
5.
Remove the power source PWB assembly
from the high voltage PWB’s connector.
Figure 1-5-31
Connector
Connector
Connector
Connector
(YC104)
Power source PWB
assembly
P tight screws
P tight screws
Ground
terminal
Screws
Connector
(YC201)
High voltage PWB
Connector