1-5-8 PWBs (1) Detaching and refitting the control PWB Procedure 1. Remove the right cover (See page 1-5-4). 2. Remove the connectors form the control PWB. Simplex model: Twelve Duplex model: Thirteen 3. Release the wires from the wire clamps. Control PWB Wire clamps 2H5/2HS Connectors Simplex model: Eleven Duplex model: Twelve A Connector A: Duplex model only Control PWB Figure 1-5-27 1-5-19
2H5/2HS
1-5-19
1-5-8
PWBs
(1) Detaching and refitting the control PWB
Procedure
1.
Remove the right cover (See page 1-5-4).
2.
Remove the connectors form the control
PWB.
Simplex model: Twelve
Duplex model: Thirteen
3.
Release the wires from the wire clamps.
Figure 1-5-27
A
Connectors
Simplex model: Eleven
Duplex model: Twelve
A: Duplex model only
Connector
Control PWB
Control PWB
Wire clamps