LG LP070HED1 Service Manual - Page 38
Volt Units
View all LG LP070HED1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 38 highlights
265 Volt Units 1. Remove and discard the red lead from the wire assembly . 2. Connect the black lead to the center terminal of the fuse holder. 3. Connect the white lead to the common (C) terminal on the capacitor. 4. Connect the ground wire to the partition panel where the ground wire on the power cord was located. Use the supplied green ground screw. 5. Connect the white lead of the wire assembly at the junction box to the white lead of the field power source. 6. Connect the black lead of the wire assembly at the junction box to the black lead of the field power source. 7. Connect the ground wire of the field power supply to the bare ground wire of the wire assembly at the junction box. 8. Install the junction box cover plate. 9. Reinstall the control panel assembly. Figure 48 - Mounting Hard Wire Junction Box Kit Wall Sleeve Cover plate Ground Wie with Eyelet Terminal 28 Inch es Max Conduit Power Leads with Push on Connectors Metal Box with Straight Clamp Figure 48 - Metal Box Location Control Panel Base Pan Bracket Figure 49 - Electrical Wiring Routing Right Side of Chassis Wire Tie 3/16 Inch Diamenter Hole Electrical Supply Wires Back of Control Panel Downloaded from www.Manualslib.com manuals search engine -38-