LG LP070HED1 Service Manual - Page 43
Part/Location Identification, Dimensions, Wiring
![]() |
View all LG LP070HED1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 43 highlights
4" (101 mm) 2-5/8" (67 mm) Note: The proper subbase must be ordered to obtain the correct electrical receptacle. (Figure 62) 8. After wiring is complete, mount covers A and F to the subbase with provided screws. (Figure 59) 9. When installing optional accessories to the subbase, refer to each installation instruction for that accessory. Figure 58 Figure 60 - Dimensions Wall Sleeve (Outdoor Side) 13 3/4" 16" 16" 2 3/4" 2 3/4" 2 5/8" Wall Sleeve Inside Edge Back of Flange "A" Left End View 2" (50 mm) Figure 59 - Part/Location Identification Part/Location Identification A Left Front Cover B Right Front Cover C Front Cord Panel D Wall Sleeve Hole Location E Skirting Hole Location F Right Cover Assembly Concentric Knockouts In Bottom Top View Ground Screw Location Receptacle Provided Inside subbase 3-1/16" Accessory 13-7/8" (352 mm) (78 mm) 20-5/16" (515.5 mm) 1-3/8" (35 mm) Concentric Knockouts In Rear Front View 2" (50 mm) Max. Adjustment Figure 61 - Wiring Diagram Wall Sleeve D E NEMA 7-20R Receptacle NEMA 7-30R Receptacle Field Wiring Line Voltage 265 VAC Field Schematic Figure 61 - NEMA Plug Configurations Voltage Unit Plug Subbase Receptacle Cover Wiring A Access B Subbase Box Assy 2-13/16" D (71 mm) F E C Low Voltage Compartment 11(-31030/1m6m" ) Downloaded from www.Manualslib.com manuals search engine -43-
![](/manual_guide/products/lg-lp070hed1-service-manual-8185f34/43.png)