Lantronix EDS3000PS Command Reference - Page 69

Commands and Levels, EDS3000 Command Reference, <line&gt, <bytes&gt, <control&gt, <text&

Page 69 highlights

6: Commands and Levels no gap timer Removes the gap timer, so forwarding depends on the line speed. no name Removes the name of this line. parity even Uses a parity bit on the line for even parity. parity none Does not use a parity bit on the line. parity odd Uses a parity bit on the line for odd parity. protocol none Uses no protocol on the line. protocol tunnel Applies tunnel protocol on the line. reassert Asserts line status with current configured values. show Displays the current status. show command mode Shows the command mode settings for the current line. show history Displays the last 20 commands entered during the current CLI session. show line Displays the current configuration. show statistics Shows the line statistics. state disable Disables the line so data cannot be sent/received. state enable Enables the line so data can be sent/received. stop bits 1 Uses one stop bit after data on the line. stop bits 2 Uses two stop bits after data on the line. terminal Enters the configure-terminal level. = number of the terminal line (serial port) to be configured. terminal network Enters the configure-terminal level for the network. threshold Sets the threshold in bytes. After this many bytes are received, they are forwarded without delay. tunnel Enters the tunnel level. = number of the tunnel line (serial port) to be configured. write Stores the current configuration in permanent memory. xoff char Sets the xoff character for use with software flow control on this line. The character may be input as text, control, decimal, or hex. A control character has the form C. A decimal value character has the form \99. A hex value character has the form 0xFF. xon char Sets the xon character for use with software flow control on this line. The character may be input as text, control, decimal, or hex. A control character has the form C. A decimal value character has the form \99. A hex value character has the form 0xFF. line (config-consoleflow-line) level commands clrscrn Clears the screen. command delimiter Sets the command delimiter. content check interval Sets the firmware and configuration check interval. default command delimiter Restores the command delimiter. default content check interval Restores the default firmware and configuration check interval. default local port Clears the local port for consoleflow client. default status update interval Restores the default status update interval. exit Exits to the config-consoleflow level. line Change to line configuration level. EDS3000 Command Reference 69

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83

6: Commands and Levels
EDS3000 Command Reference
69
no gap timer
Removes the gap timer, so forwarding depends on the line speed.
no name
Removes the name of this line.
parity even
Uses a parity bit on the line for even parity.
parity none
Does not use a parity bit on the line.
parity odd
Uses a parity bit on the line for odd parity.
protocol none
Uses no protocol on the line.
protocol tunnel
Applies tunnel protocol on the line.
reassert
Asserts line status with current configured values.
show
Displays the current status.
show command mode
Shows the command mode settings for the current line.
show history
Displays the last 20 commands entered during the current CLI session.
show line
Displays the current configuration.
show statistics
Shows the line statistics.
state disable
Disables the line so data cannot be sent/received.
state enable
Enables the line so data can be sent/received.
stop bits 1
Uses one stop bit after data on the line.
stop bits 2
Uses two stop bits after data on the line.
terminal
<line>
Enters the configure-terminal level. <line> = number of the terminal line
(serial port) to be configured.
terminal network
Enters the configure-terminal level for the network.
threshold
<bytes>
Sets the threshold in bytes. After this many bytes are received, they are
forwarded without delay.
tunnel
<line>
Enters the tunnel level. <line> = number of the tunnel line (serial port) to be
configured.
write
Stores the current configuration in permanent memory.
xoff char
<control>
Sets the xoff character for use with software flow control on this line. The
character may be input as text, control, decimal, or hex. A control character
has the form <control>C. A decimal value character has the form \99. A
hex value character has the form 0xFF.
xon char
<control>
Sets the xon character for use with software flow control on this line. The
character may be input as text, control, decimal, or hex. A control character
has the form <control>C. A decimal value character has the form \99. A
hex value character has the form 0xFF.
line <number> (config-consoleflow-line<number>) level commands
clrscrn
Clears the screen.
command delimiter
<text>
Sets the command delimiter.
content check interval
<hours>
Sets the firmware and configuration check interval.
default command delimiter
Restores the command delimiter.
default content check
interval
Restores the default firmware and configuration check interval.
default local port
Clears the local port for consoleflow client.
default status update
interval
Restores the default status update interval.
exit
Exits to the config-consoleflow level.
line
<number>
Change to line configuration level.