Lenovo PC 300 IBM PC300 (Type 2169) - Hardware Maintenance Manual (September 2 - Page 78

BIOS Error Codes, Messages, and Beeps List, Hard Disk Drive Jumper Locations

Page 78 highlights

Table 2-1 BIOS Error Codes, Messages, and Beeps List BIOS Error Codes, Action/FRU Messages, beeps NOTE: To diagnose a problem, first find the BIOS error messages, codes, or beeps in left column. If directed to a check procedure, replace the FRU indicated in the check procedure. If no check procedure is indicated, the first Action/FRU listed in right column is the most likely cause. Memory test failure. Insert the memory modules in the DIMM sockets properly, and then reboot the system. Keyboard error or no keyboard present. Memory module. See the "Step 005" of "Memory" on page 95 to replace memory module. System board. Make sure the keyboard is connected properly and are set correctly in BIOS Setup. System board. FLOPPY DISK(S) failure (40) Floppy Type mismatch. Hard disk(s) Diagnosis failure Make sure the hard disks are set correctly in BIOS setup. Hard disk drive cable/connection. Hard disk drive. System board. Primary master hard disk failure Primary slave hard disk failure A warning message to indicate there has been change of IDE Primary (Secondary) Channel Master (Slave) device. Load default settings in Setup. Check IDE drive jumper. See "3.5-In. Hard Disk Drive Jumper Locations" on page 133. IDE drive power. IDE drive cable/connection. IDE drive. 76

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157

76
Table 2-1
BIOS Error Codes, Messages, and Beeps List
BIOS Error Codes,
Messages, beeps
Action/FRU
NOTE:
To diagnose a problem, first find the BIOS error
messages, codes, or beeps in left column.
If directed to a
check procedure, replace the FRU indicated in the check
procedure.
If no check procedure is indicated, the first
Action/FRU listed in right column is the most likely cause.
Memory test failure.
Insert the memory modules in the
DIMM sockets properly, and then
reboot the system.
Memory module.
See the “Step 005”
of ”Memory” on page 95 to replace
memory module.
System board.
Keyboard error or no
keyboard present.
Make sure the keyboard is connected
properly and are set correctly in BIOS
Setup.
System board.
FLOPPY DISK(S)
failure (40)
Floppy Type mismatch.
Hard disk(s)
Diagnosis failure
Make sure the hard disks are set
correctly in BIOS setup.
Hard disk drive cable/connection.
Hard disk drive.
System board.
Primary master hard
disk failure
Primary slave hard
disk failure
A warning message to indicate there
has been change of IDE Primary
(Secondary) Channel Master (Slave)
device.
Load default settings in Setup.
Check IDE drive jumper.
See “3.5-In.
Hard Disk Drive Jumper Locations” on
page 133.
IDE drive power.
IDE drive cable/connection.
IDE drive.