Lenovo PC 300 IBM PC300 (Type 2169) - Hardware Maintenance Manual (September 2 - Page 79

Hard Disk Drive Jumper Locations on, Hard Disk Drive controller diagnostics

Page 79 highlights

Table 2-1 BIOS Error Codes, Messages, and Beeps List BIOS Error Codes, Action/FRU Messages, beeps NOTE: To diagnose a problem, first find the BIOS error messages, codes, or beeps in left column. If directed to a check procedure, replace the FRU indicated in the check procedure. If no check procedure is indicated, the first Action/FRU listed in right column is the most likely cause. Secondary master hard disk failure A warning message to indicate there has been change of IDE Primary (Secondary) Channel Master (Slave) device. Load default settings in Setup. Secondary slave hard disk failure Check IDE drive jumper. See "3.5-In. Hard Disk Drive Jumper Locations" on page 133. IDE drive power. Hard Disk(s) failure (40) IDE drive cable/connection. IDE drive. Hard Disk Drive controller diagnostics failed. Non-System disk or Insert a system disk into Drive A: and disk error press . Replace and strike any key when ready If you assumed the system would boot from the hard drive, make sure the controller is inserted correctly and all cables are properly attached. Be sure the disk is formatted as a boot device. Then reboot the system. 77

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157

77
Table 2-1
BIOS Error Codes, Messages, and Beeps List
BIOS Error Codes,
Messages, beeps
Action/FRU
NOTE:
To diagnose a problem, first find the BIOS error
messages, codes, or beeps in left column.
If directed to a
check procedure, replace the FRU indicated in the check
procedure.
If no check procedure is indicated, the first
Action/FRU listed in right column is the most likely cause.
Secondary master
hard disk failure
Secondary slave hard
disk failure
A warning message to indicate there
has been change of IDE Primary
(Secondary) Channel Master (Slave)
device.
Load default settings in Setup.
Check IDE drive jumper. See ”3.5-In.
Hard Disk Drive Jumper Locations” on
page 133.
IDE drive power.
IDE drive cable/connection.
IDE drive.
Hard Disk(s) failure
(40)
Hard Disk Drive controller diagnostics
failed.
Non-System disk or
disk error
Replace and strike
any key when ready
Insert a system disk into Drive A: and
press <
Enter
>.
If you assumed the system would boot
from the hard drive, make sure the
controller is inserted correctly and all
cables are properly attached.
Be sure the disk is formatted as a boot
device.
Then reboot the system.