Lenovo PC 300 IBM PC300 (Type 2169) - Hardware Maintenance Manual (September 2 - Page 83

Table 2-3 Error Symptoms List, Error Symptoms, Action/FRU, Hard Disk Drive

Page 83 highlights

Table 2-3 Error Symptoms List Error Symptoms Action/FRU NOTE: To diagnose a problem, first find the error symptom in the left column. If directed to a check procedure, replace the FRU indicated in the check procedure. If no check procedure is indicated, the first Action/FRU listed in right column is the most likely cause. Media and drive are mismatched. Make sure that the diskette drive is configured correctly in the Disk Drives of BIOS Setup. Make sure that the diskette drive is correctly formatted. Diskette drive connection/cable Diskette drive System board Diskette drive does not work. Make sure that the onboard FDC controller is not set to disabled in the BIOS Setup utility. Diskette drive power Diskette drive connection/cable Diskette drive System board Diskette drive test failed. Diskette Diskette drive Diskette drive cable System board Hard Disk Drive NOTE: Ensure hard disk drive is configured correctly in BIOS Setup, cable/jumper are set correctly before diagnosing any hard disk drive problems. Hard disk drive test failed. Load default settings. Hard disk drive cable. Hard disk drive. System board. Hard disk drive format Load default settings. error. Hard disk drive cable. Hard disk drive. System board. Hard disk drive write Load default settings. error. Hard disk drive. 81

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157

81
Table 2-3 Error Symptoms List
Error Symptoms
Action/FRU
NOTE:
To diagnose a problem, first find the error symptom
in the left column. If directed to a check procedure, replace the
FRU indicated in the check procedure.
If no check procedure
is indicated, the first Action/FRU listed in right column is the
most likely cause.
Media and drive are
mismatched.
Make sure that the diskette drive is
configured correctly in the Disk Drives
of BIOS Setup.
Make sure that the diskette drive is
correctly formatted.
Diskette drive connection/cable
Diskette drive
System board
Diskette drive does
not work.
Make sure that the onboard FDC
controller is not set to disabled in the
BIOS Setup utility.
Diskette drive power
Diskette drive connection/cable
Diskette drive
System board
Diskette drive test
failed.
Diskette
Diskette drive
Diskette drive cable
System board
Hard Disk Drive
NOTE:
Ensure hard disk drive is configured correctly in
BIOS Setup, cable/jumper are set correctly before diagnosing
any hard disk drive problems.
Hard disk drive test
failed.
Load default settings.
Hard disk drive cable.
Hard disk drive.
System board.
Hard disk drive format
error.
Load default settings.
Hard disk drive cable.
Hard disk drive.
System board.
Hard disk drive write
error.
Load default settings.
Hard disk drive.