Motorola 49901 Software Release Notes - Page 37

All Vanguards - Directory Limitation when Creating Images, Customer Initiated, Change Requests, Change

Page 37 highlights

Software Improvements Part No. T0001-42, Rev C October, 2002 Page 37 of 103 All Vanguards - Directory Limitation when Creating Images Vanguide Application Builder and Service Patches can only be installed under a directory that is no more than eight characters (DOS 8.3 format), since Vanguide Builder calls a third party image LINKER which only supports the directory/file name in DOS 8.3 format. (DRFaa19749) This is fixed Customer Initiated Change Requests These Change Requests were reported to Customer Service and interim patch releases were released to fix the problems. These Change Requests are incorporated into Release 6.1.R000, and where applicable, interim patch releases have been replaced by Release 6.1.R000: Change Request (CR#) N/A 10182 10228 10590 11067 11088 11098 11121 Limitation Number DRCaa23154 DRFaa15526 DRFaa15547 DRFaa16919 DRFaa18471 DRFaa18580 DRFaa19671 DRFaa18638 Release Where Problem Was Reported 6.0.R000 5.4.P0CA 5.4 5.4.P0CB 5.4.SBI 5.6.R000 5.3.MC1 5.6.T16A Interim Patch Release Replaced by Release 6.1 6.0.T01A 5.4.P0CC 6.0.T11A 5.4.P0CC 5.4.T7FA N/A 5.6.T4BA 5.6.T2GB Problem Description Vanguard 7300 continually crashes with very large ATM and Frame Relay configurations. Multiple ping SNMP feature was not working correctly. Vanguard 6560, 7300 Series RIP default route is advertised unconditionally when enabled on the interface. Multiple ping SNMP support of a larger instance number. Vanguard 6560 node crashed with FAULT: Unassigned interrupt encountered. The internal IP address information is not available in the ipAddress Table and the interface Table of the MIB2 agent. Vanguard 6560 sends a frame reject which terminates the LLC session. When the PBX sends a RESTART packet, the Vanguard 6455 does not respond with RESTART ACKNOWLEDGE packet.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103

Part No. T0001-42, Rev C
October, 2002
Software Improvements
Page 37 of 103
All Vanguards - Directory Limitation when Creating Images
Vanguide Application Builder and Service Patches can only be installed under a
directory that is no more than eight characters (DOS 8.3 format), since Vanguide
Builder calls a third party image LINKER which only supports the directory/file
name in DOS 8.3 format. (DRFaa19749)
This is fixed
Customer Initiated
Change Requests
These Change Requests were reported to Customer Service and interim patch
releases were released to fix the problems. These Change Requests are incorporated
into Release 6.1.R000, and where applicable, interim patch releases have been
replaced by Release 6.1.R000:
Change
Request
(CR#)
Limitation
Number
Release Where
Problem Was
Reported
Interim Patch
Release
Replaced by
Release 6.1
Problem Description
N/A
DRCaa23154
6.0.R000
6.0.T01A
Vanguard 7300 continually
crashes with very large ATM and
Frame Relay configurations.
10182
DRFaa15526
5.4.P0CA
5.4.P0CC
Multiple ping SNMP feature was
not working correctly.
10228
DRFaa15547
5.4
6.0.T11A
Vanguard 6560, 7300 Series RIP
default route is advertised
unconditionally when enabled on
the interface.
10590
DRFaa16919
5.4.P0CB
5.4.P0CC
Multiple ping SNMP support of a
larger instance number.
11067
DRFaa18471
5.4.SBI
5.4.T7FA
Vanguard 6560
node crashed
with FAULT: Unassigned
interrupt encountered.
11088
DRFaa18580
5.6.R000
N/A
The internal IP address
information is not available in the
ipAddress Table
and the
interface
Table
of the MIB2 agent.
11098
DRFaa19671
5.3.MC1
5.6.T4BA
Vanguard 6560
sends a frame
reject which terminates the
LLC session.
11121
DRFaa18638
5.6.T16A
5.6.T2GB
When the PBX sends a
RESTART packet, the Vanguard
6455 does not respond with
RESTART ACKNOWLEDGE
packet.