Oki OF5800 Service Guide - Page 158
eliminated by changing Unique Switch H:2, bit 7, to a 1. Changing this setting will allow
![]() |
View all Oki OF5800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 158 highlights
Service Manual for OF5800 Chapter 3 Adjustment Procedures Page: 139 The images stored in DRAM are protected by battery backup for up to 108 hours for a single event in a 40 hour period. In other words, once power is lost and then restored, the unit will not backup documents for the next 40 hours. This time frame allows the batteries to fully recharge. This 40 hour time period can be eliminated by changing Unique Switch H:2, bit 7, to a 1. Changing this setting will allow the technician to turn power off several times while repairing the unit and not lose any documents stored in memory. Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business Partner Exchange (BPX) for any updates to this material. (http://bpx.okidata.com)
![](/manual_guide/products/oki-data-of5800-service-guide-82947a4/158.png)