Black s, Printout too light, Blurred background
View all Oki OF5800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 174 highlights
Black pages Printout too light Printout too dark Blurred background Verify that the drum and toner cartridge are installed properly. Remove the drum cartridge and clean the contacts on the toner cartridge inside the unit. If the problem persists, replace the drum. Replace the drum cartridge. Replace the print head unit. Replace the high voltage power supply. Replace the printer mechanical controller Replace the printer interface pcb. Replace the main control board. Remove the Toner Cartridge and shake it a few times to redistribute the toner inside. Remove the drum cartridge and clean the contacts on the toner cartridge inside the unit. If the problem persists, replace the drum. Verify that a clear image is being placed on the drum by printing a document and opening the printer cover before the document completes printing. At this point remove the drum and check for a clear image on the drum. If there is a clear image on the drum, the problem could be caused by poor image transfer. Replace the image transfer unit and/or the high voltage power supply and/or the printer mechanical controller and/or the main control board. Remove the Toner Cartridge and shake it a few times to redistribute the toner inside. If the problem persists, replace the Toner Cartridge. Verify operation of the drum unit. Verify that a clear image is being placed on the drum by printing a document and opening the printer cover before the document completes printing. At this point remove the drum and check for a clear image on the drum. If there is a clear image on the drum, the problem could be caused by poor image transfer. Replace the image transfer unit and/or the high voltage power supply and/or the main control board and/or the printer mechanical controller. Insure the drum and toner cartridge are installed correctly. Replace drum cartridge. Remove the toner cartridge and clean the contacts on the toner cartridge and inside the unit. If the problem persists replace the toner cartridge. Replace the high voltage power supply. Replace the printer mechanical controller pcb. Replace the main control board.