11-1. Parallel Interface Model ON ON OFF No. 1 2 3 4 5 6 7 8 9 10 DIP-SW 1 OFF No. 1 2 3 4 DIP-SW 2 Switch 1-1 ON OFF DIP-SW 1 The factory settings of DIP switch are all on. Command emulation Star Mode ESC/POS Mode The functions of switches 1-2 through 1-10 will change according to the command emulation that has been set using switch 1-1. (1) Star mode Switch Function 1-1 Command emulation 1-2 Should not be changed (Should be set to on) 1-3 Should not be changed (Should be set to on) 1-4 Sensor adjustment 1-5 Pin #31 (INIT) reset signal 1-6 Handshaking conditions (conditions for BUSY) 1-7 Automatic status back function 1-8 Should not be changed (Should be set to on) 1-9 Low-power consumption mode 1-10 Should not be changed (Should be set to on) (2) ESC/POS mode Switch Function 1-1 Command emulation 1-2 Graphic adjustment 1-3 Should not be changed (Should be set to on) 1-4 Sensor adjustment 1-5 Pin #31 (INIT) reset signal 1-6 Handshaking conditions (conditions for BUSY) 1-7 Automatic status back function 1-8 Should not be changed (Should be set to on) 1-9 Low-power consumption mode 1-10 Should not be changed (Should be set to on) ON Always ON Invalid Valid Offline or receive buffer full Invalid Invalid ON Always OFF 203 DPI Invalid Valid Offline or receive buffer full Invalid Invalid OFF Valid Invalid Receive buffer full Valid Valid OFF 180 DPI Valid Invalid Receive buffer full Valid Valid - 41 -