Oki OKIPOS 407II ParallelBlack Users Guide - Page 49
Change the setting of the DIP switches.
View all Oki OKIPOS 407II ParallelBlack manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 49 highlights
The following is the procedure for changing the settings on DIP switch No. 3. 1. Turn off the printer and all components connected to it. 2. Remove the 2 screws. 3. Remove the serial interface board unit. 4. Change the setting of the DIP switches. 5. Replace the serial interface board unit. Then secure it with the screws. 6. Turn on the printer and all components connected to it. DIP switch 3 ON OFF No. 1 2 3 4 5 6 7 8 DIP-SW 3 The factory settings of DIP switch are all on, except for switches 7 and 8. Switch 3-1 3-2 3-3 3-4 3-5 3-6 3-7 3-8 Function DIP-SW 3 Baud Rate Data Length Parity Check Parity Handshake Should not be changed (Should be set to off) ON OFF See table below 8 bits Disabled Odd DTR/DSR 7 bits Enabled Even XON/XOFF - - Baud Rate 4800BPS 9600BPS 19200BPS 38400BPS Switch 3-1 OFF ON ON OFF Switch 3-2 ON ON OFF OFF - 45 -