Pioneer DRM-1004 Operating Instructions - Page 15
Specifications
View all Pioneer DRM-1004 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
SPECIFICATIONS ■ General System 100 disc changer Power requirements AC 100V/120V/230V (switchable) 50/60 Hz Current drain 1.6A(100V) 1.4A(120V) 1.0A(230V) Weight (with disc magazine, without discs) 28.1 kg (61 lb 15 oz) Dimensions 263 (W) x 484 (H) x 588 (D) mm 10-11/32 (W) x 19-1/16 (HI x 23-1/8 (D) in Operating temperature +5°C - +35°C" +41°F - +95°F" Operating humidity 5% - 85% (no condensation)" Storage temperature -40°C - +60°C -40°F - +140°F ■ Functions Disc storage (12 cm/5-inch discs) 100 discs Removable disc magazines 2 magazines which hold 50 discs each can be stored. ■ Accessories Door key (for front door locking) 2 Power cord 2 Operating Instructions 1 NOTE: • Specifications and design are subject to possible modifications without notice, due to improvements. Because the allowed operating temperature and the allowed operating humidity are limited by the drive that is installed, be sure to use the drive under the conditions stipulated in the operating instructions for the drive. SCSI connector specifications lllllll I y ' 11111111111111111LLLLLLL 1) Pin layout of SCSI connectors Signal name Pin No. GROUND GROUND GROUND GROUND GROUND GROUND GROUND GROUND GROUND GROUND GROUND GROUND NC GROUND GROUND GROUND GROUND GROUND GROUND GROUND GROUND GROUND GROUND GROUND GROUND 1 26 2 27 3 28 4 29 5 30 6 31 7 32 8 33 9 34 10 35 11 36 12 37 13 38 14 39 15 40 16 41 17 42 18 43 19 44 20 45 21 46 22 47 23 48 24 49 25 50 Signal name -DB(0) -DB(1) -DB(2) -DB(3) -DB(4) -DB(5) -DB(6) -DB(7) -DB(P) GROUND GROUND GROUND TERMPWR GROUND GROUND -ATN GROUND -BSY -ACK -RST -MSG -SEL -C/D -REQ -I/O Notes: • For safety, this unit has been designed so that the door cannot be opened while the built-in reader is operating. • Since the disc rotates at a high speed in the built-in reader, vibrations or noise may be generated as a result. Note that this is not a malfunction and thatit willnot exert adverse effects on the performance of the unit. Maintenance In order to ensure safe and proper functioning of this unit, we recommend regular maintenance. Extended service life can be expected if maintained properly. Notes: • Pin No. 13 is not grounded. • The connectors are of the shielded type. • For details on the control commands, refer to the separate specifications manual. 2) Electrical specifications of SCSI Output characteristics The signals driven by SCSI equipment present the following output characteristics. True (LOW): VOL = 0.0 to 0.5 V DC IOL = 48 mA (0.5 V DC) max. False (HIGH): VOH = 2.5 to 5.25 V DC Input characteristics The signals driven by SCSI equipment present the following input characteristics. True (LOW): VOL = 0.0 to 0.8 V DC IOL = -0.4 mA to 0.0 mA (0.5 V DC) False (HIGH): VOH = 2.0 to 5.25 V DC Notes: • Terminate it at both ends of the SCSI bus. • The SCSI interface is single-end type. • Use an SCSI-use high impedance cable (characteristic impedance: 100 ± 1012) with a maximum length of 6 m (total length including the wiring inside the unit). Published by ['weer Corporation. Copyright @ 1999 Pioneer Corporation. All rights reserved. 15 En