Ridgid 100-B Owners Manual - Page 16

Troubleshooting

Page 16 highlights

Compact 100-B Pressing Tool Troubleshooting SYMPTOM POSSIBLE REASONS SOLUTION Tool will not turn ON when ON/OFF button on display panel is pressed. Tool turns OFF either when trigger is depressed or in the middle of a press cycle. Red LED alarm blinks 5 times then the tool shuts off automatically. Battery is completely discharged or battery has failed. Battery not properly inserted into handle of tool. Battery is too low. Battery is too cold. Yellow LED blinks repeatedly as long as tool is turned ON and tool functions properly. Scheduled maintenance/recalibration is required after 20,000 presses. Yellow LED glows continuously and tool will not begin press cycle when trigger switch is depressed. Scheduled maintenance/recalibration is mandatory after 22,000 presses. Tool is "locked" and will not function until tool is serviced. Red LED blinks repeatedly and tool will not begin press cycle when trigger switch is depressed. Jaw mounting pin not fully closed. Temperature out of range. Red LED and yellow LED Tool malfunction detected. both glow continuously when tool is turned ON. Insert fully charged battery/recharge dead battery. Check to assure battery is fully inserted. Insert fully charged battery/recharge dead battery. Warm battery to range of 32°F (0°C) to 122°F (50°C). NOTE! Fitting must be repressed if tool stops in the middle of a press cycle. Failure to do so may result in a leaking fitting. Contact Ridge Tool Company, Technical Service Department at (800) 519-3456 for nearest Authorized Service outlet. Contact Ridge Tool Company, Technical Service Department at (800) 519-3456 for nearest Authorized Service outlet. Insert jaw mounting pin to the fully closed position. Bring tool and battery to the range of 32°F (0°C) to 122°F (50°C). Remove and reinsert fully charged battery. If LED's continue to glow, contact Ridge Tool Company, Technical Service Department at (800) 519-3456 for nearest Authorized Service outlet. 14 Ridge Tool Company

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

Compact 100-B Pressing Tool
Ridge Tool Company
14
SYMPTOM
POSSIBLE REASONS
SOLUTION
Tool will not turn ON
when ON/OFF button on
display panel is pressed.
Tool turns OFF either
when trigger is de-
pressed or in the middle
of a press cycle. Red
LED alarm blinks 5 times
then the tool shuts off
automatically.
Yellow LED blinks
repeatedly as long as
tool is turned ON and
tool functions properly.
Yellow LED glows con-
tinuously and tool will
not begin press cycle
when trigger switch is
depressed.
Red LED blinks repeated-
ly and tool will not begin
press cycle when trigger
switch is depressed.
Red LED and yellow LED
both glow continuously
when tool is turned ON.
Troubleshooting
Battery is completely discharged or battery has
failed.
Battery not properly inserted into handle of tool.
Battery is too low.
Battery is too cold.
Scheduled maintenance/recalibration is required
after 20,000 presses.
Scheduled maintenance/recalibration is manda-
tory after 22,000 presses. Tool is “locked” and
will not function until tool is serviced.
Jaw mounting pin not fully closed.
Temperature out of range.
Tool malfunction detected.
Insert fully charged battery/recharge dead battery.
Check to assure battery is fully inserted.
Insert fully charged battery/recharge dead battery.
Warm battery to range of 32°F (0°C) to 122°F
(50°C).
NOTE!
Fitting must be repressed if tool stops
in the middle of a press cycle. Failure
to do so may result in a leaking fitting.
Contact Ridge Tool Company, Technical Service
Department at (800) 519-3456 for nearest
Authorized Service outlet.
Contact Ridge Tool Company, Technical Service
Department at (800) 519-3456 for nearest
Authorized Service outlet.
Insert jaw mounting pin to the fully closed position.
Bring tool and battery to the range of 32°F (0°C) to
122°F (50°C).
Remove and reinsert fully charged battery. If LED’s
continue to glow, contact Ridge Tool Company,
Technical Service Department at (800) 519-3456 for
nearest Authorized Service outlet.