Ridgid 100-B Owners Manual - Page 17

Compact 100-B Diagnostic Codes

Page 17 highlights

Compact 100-B Pressing Tool Compact 100-B Diagnostic Codes SERVICE MAINTENANCE REQUIRED BLINKING LIGHT TEMPERATURE JAW PIN OPEN BLINKING LIGHT LOW BATTERY SERVICE ON/OFF YELLOW SOLID LIGHT RED SOLID LIGHT GREEN LED DISPLAY GREEN RED YELLOW Blink 1x Blink 1x Blink 1x Solid Solid Blinking Blink 5x Blink 5x Solid Blinking MEANING Power-up light check. Operate mode. Jaw pin open. Temperature out of range. Low Battery. Maintenance due (>20,000 presses). Solid Solid Maintenance required (>22,000 presses). Solid Solid Tool locked due to malfunctions. Blink Blink 20 Sec 20 Sec. Tool overheated/excessive current draw due to tool malfunction. ACTION - Tool is ready to press. Check jaw mounting pin to assure fully inserted. Bring tool battery to range >32°F or

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

Compact 100-B Pressing Tool
Ridge Tool Company
15
Compact 100-B Diagnostic Codes
SERVICE
YELLOW
SERVICE
MAINTENANCE
REQUIRED
SOLID LIGHT
BLINKING
LIGHT
TEMPERATURE
RED
JAW PIN OPEN
LOW BATTERY
GREEN
LED DISPLAY
GREEN
RED
YELLOW
MEANING
ACTION
Blink 1x
Blink 1x
Blink 1x
Power-up light check.
Solid
Operate mode.
Tool is ready to press.
Solid
Blinking
Jaw pin open.
Check jaw mounting pin to assure fully inserted.
Temperature out of range.
Bring tool battery to range >32°F or <122°F
Blink 5x
Blink 5x
Low Battery.
Replace or recharge battery.
NOTE! Repeat Press.
Solid
Blinking
Maintenance due (>20,000 presses).
Contact Ridge Tool Company, Technical Service
Department at (800) 519-3456 for nearest Authorized
Service outlet.
Solid
Solid
Maintenance required (>22,000 presses).
Contact Ridge Tool Company, Technical Service
Department at (800) 519-3456 for nearest Authorized
Service outlet.
Solid
Solid
Tool locked due to malfunctions.
Remove and replace battery. If still locked, contact Ridge
Tool Company, Technical Service Department at (800)
519-3456 for nearest Authorized Service outlet.
Blink
Blink
Tool overheated/excessive current draw due to
Allow tool to cool for 20 seconds. If condition occurs
20 Sec
20 Sec.
tool malfunction.
repeatedly, contact Ridge Tool Company, Technical Service
Department at (800) 519-3456 for nearest Authorized
Service outlet.
SOLID LIGHT
BLINKING
LIGHT
ON/OFF