Sanyo PLC-WL2503 RS232C Expand - Page 24

CF_DLINE Command, CF_PCSTORE Command, CF_PCMODEFREE Command

Page 24 highlights

PLC-WL2500 / WL2501/ WL2503 Expand Serial Command Functional Specifications 8.5.7 CF_DLINE Command Command "CF_DLINE_%1"[CR] "0100"~"nnnn" --- Directly select Display Line setting value "nnnn" shows maximum value, it is current Total Line value - Vertical %1 Position value "UP Current Display Line setting value + 1 "DN Current Display Line setting value - 1 Details Set Display Line value of PC signal The value set by this command will not be saved to projector. Therefore, when turning into Standby status or ALL is OFF, the value returns to original setting. This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 8.5.8 CF_PCSTORE Command Command "CF_PCSTORE_%1"[CR] "MODE1" ------ Store current PC Adjust status to Mode1 "MODE2" ------ Store current PC Adjust status to Mode2 "MODE3" ------ Store current PC Adjust status to Mode3 "MODE4" ------ Store current PC Adjust status to Mode4 %1 "MODE5" ------ Store current PC Adjust status to Mode5 "MODE6" ------ Store current PC Adjust status to Mode6 "MODE7" ------ Store current PC Adjust status to Mode7 "MODE8" ------ Store current PC Adjust status to Mode8 "MODE9" ------ Store current PC Adjust status to Mode9 "MODE10" ---- Store current PC Adjust status to Mode10 Details Store current PC Adjust status (each parameter status such as Total dots) to Mode1~Mode10. This command operates the same as storing to Mode1-Mode10 in PC Adjust MENU. This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 8.5.9 CF_PCMODEFREE Command Command "CF_PCMODEFREE_%1"[CR] "MODE1" ------ Set Mode1 to Free status "MODE2" ------ Set Mode2 to Free status "MODE3" ------ Set Mode3 to Free status "MODE4" ------ Set Mode4 to Free status %1 "MODE5" ------ Set Mode5 to Free status "MODE6" ------ Set Mode6 to Free status "MODE7" ------ Set Mode7 to Free status "MODE8" ------ Set Mode8 to Free status "MODE9" ------ Set Mode9 to Free status "MODE10" ---- Set Mode10 to Free status Details Delete the registered data in Mode1-Mode5 and turns it to Free status. This command operates the same as turning Mode1-Mode5 to Free in PC Adjust Menu. This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 23/72

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73

PLC-WL2500 / WL2501/ WL2503
Expand Serial Command Functional Specifications
23/72
8.5.7
CF_DLINE Command
Command
“CF_DLINE_%1”[CR]
%1
“0100”~”nnnn” --- Directly select Display Line setting value
“nnnn” shows maximum value, it is current Total Line value – Vertical
Position value
“UP” -------------- Current Display Line setting value + 1
“DN” -------------- Current Display Line setting value – 1
Details
Set Display Line value of PC signal
The value set by this command will not be saved to projector. Therefore, when
turning into Standby status or ALL is OFF, the value returns to original setting.
This command is available in normal Power ON status.
Acceptable
“000”[CR]
Response
Unacceptable
“Error Code”[CR]
8.5.8
CF_PCSTORE Command
Command
“CF_PCSTORE_%1”[CR]
%1
“MODE1” ------ Store current PC Adjust status to Mode1
“MODE2” ------ Store current PC Adjust status to Mode2
“MODE3” ------ Store current PC Adjust status to Mode3
“MODE4” ------ Store current PC Adjust status to Mode4
“MODE5” ------ Store current PC Adjust status to Mode5
“MODE6” ------ Store current PC Adjust status to Mode6
“MODE7” ------ Store current PC Adjust status to Mode7
“MODE8” ------ Store current PC Adjust status to Mode8
“MODE9” ------ Store current PC Adjust status to Mode9
“MODE10” ---- Store current PC Adjust status to Mode10
Details
Store current PC Adjust status (each parameter status such as Total dots) to
Mode1~Mode10. This command operates the same as storing to Mode1-Mode10
in PC Adjust MENU.
This command is available in normal Power ON status.
Acceptable
“000”[CR]
Response
Unacceptable
“Error Code”[CR]
8.5.9
CF_PCMODEFREE Command
Command
“CF_PCMODEFREE_%1”[CR]
%1
“MODE1” ------ Set Mode1 to Free status
“MODE2” ------ Set Mode2 to Free status
“MODE3” ------ Set Mode3 to Free status
“MODE4” ------ Set Mode4 to Free status
“MODE5” ------ Set Mode5 to Free status
“MODE6” ------ Set Mode6 to Free status
“MODE7” ------ Set Mode7 to Free status
“MODE8” ------ Set Mode8 to Free status
“MODE9” ------ Set Mode9 to Free status
“MODE10” ---- Set Mode10 to Free status
Details
Delete the registered data in Mode1-Mode5 and turns it to Free status.
This command operates the same as turning Mode1-Mode5 to Free in PC Adjust
Menu.
This command is available in normal Power ON status.
Acceptable
“000”[CR]
Response
Unacceptable
“Error Code”[CR]