Sanyo PLC-WL2503 RS232C Expand - Page 37

CF_DISP Command, 10.8 CF_LOGO Command

Page 37 highlights

PLC-WL2500 / WL2501/ WL2503 Expand Serial Command Functional Specifications 8.10.7 CF_DISP Command Command "CF_DISP_%1"[CR] "ON Select Display "OFF Cancel Display "CNTDWNOFF Count down OFF %1 "UP Switch Display mode forward (On → Countdown OFF → Off → On →...) "DN Switch Display mode backward (On → Off → Countdown OFF → On →...) Details Set / Cancel Display The value set by this command is stored in EEPROM and its setting is effective even after ALL is OFF. This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 8.10.8 CF_LOGO Command Command "CF_LOGO_%1_%2"[CR] %1 "0000"-"9999 Set LOGO PIN CODE directly "OFF Disable Logo function "DFLT Display Default Logo "USER Display Captured Logo %2 "UP Switch Logo setting forward (OFF → DFLT → User → OFF → ) "DN Switch Logo setting backward (OFF → User → DFLT → OFF → ) Set / Cancel Logo The value set by this command is stored in EEPROM and its setting is effective even after ALL is OFF This command is available in normal Power ON status. %1--- Set LOGO PIN CODE Details - When LOGO LOCK is in operation PIN CODE is correct Command is valid (Acceptable) PIN CODE is incorrect Command is invalid (Error Code "102") PIN CODE is out of %1 range ------ Command is invalid (Error Code "? ") -When LOGO LOCK is not in operation PIN CODE is within %1 range ------ Command is valid PIN CODE is out of %1 range ------ Command is invalid (Error Code "? ") Note) Receiving correct LOGO PIN CODE while LOGO LOCK is in operation enables to change LOGO setting, but it does not release LOGO LOCK. (LOGO LOCK continues.) Projector returns Error Code "101" by receiving USER in %2 when capture has not operated. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 36/72

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73

PLC-WL2500 / WL2501/ WL2503
Expand Serial Command Functional Specifications
36/72
8.10.7 CF_DISP Command
Command
“CF_DISP_%1”[CR]
%1
“ON” ----------------------------- Select Display
“OFF” --------------------------- Cancel Display
“CNTDWNOFF” -------------- Count down OFF
“UP” --------------- Switch Display mode forward
(On
Countdown OFF
Off
On
…)
“DN” --------------- Switch Display mode backward
(On
Off
Countdown OFF
On
…)
Details
Set / Cancel Display
The value set by this command is stored in EEPROM and its setting is effective
even after ALL is OFF.
This command is available in normal Power ON status.
Acceptable
“000”[CR]
Response
Unacceptable
“Error Code”[CR]
8.10.8 CF_LOGO Command
Command
“CF_LOGO_%1_%2”[CR]
%1
“0000”-”9999” ----------------- Set LOGO PIN CODE directly
%2
“OFF” ---------------------------- Disable Logo function
“DFLT” --------------------------- Display Default Logo
“USER” -------------------------- Display Captured Logo
“UP” --------------- Switch Logo setting forward
(OFF
DFLT
User
OFF
��
)
“DN” --------------- Switch Logo setting backward
(OFF
User
DFLT
OFF
��
)
Details
Set / Cancel Logo
The value set by this command is stored in EEPROM and its setting is effective
even after ALL is OFF
This command is available in normal Power ON status.
%1--- Set LOGO PIN CODE
- When LOGO LOCK is in operation
PIN CODE is correct ------------------ Command is valid (Acceptable)
PIN CODE is incorrect ---------------- Command is invalid (Error Code “102”)
PIN CODE is out of %1 range ------ Command is invalid (Error Code “? “)
-When LOGO LOCK is not in operation
PIN CODE is within %1 range ------ Command is valid
PIN CODE is out of %1 range ------ Command is invalid (Error Code “? “)
Note) Receiving correct LOGO PIN CODE while LOGO LOCK
is in operation
enables to change LOGO setting, but it does not release LOGO LOCK. (LOGO
LOCK continues.)
Projector returns Error Code “101” by receiving USER in %2 when capture has not
operated.
Acceptable
“000”[CR]
Response
Unacceptable
“Error Code”[CR]