PLC-WL2500 / WL2501/ WL2503 Expand Serial Command Functional Specifications 9.11.14 CR_P-MANE Command Command "CR_P-MANE"[CR] Details Get Power management setting status Acceptable "000_%a"[CR] "OFF Power Management is OFF Response %a "READY Power Management is Ready "SHUTDOWN" ---- Power Management is set to Shut Down mode Unacceptable "Error code"[CR] 9.11.15 CR_P-MANETIME Command Command "CR_P-MANETIME"[CR] Details Get time to start Power Management Acceptable "000_%a"[CR] Response %a "001"~"030 1 minute to 30 minutes Unacceptable "Error code"[CR] 9.11.16 CR_ON-STA Command Command "CR_ON-STA"[CR] Details Get Direct on setting status Acceptable "000_%a"[CR] Response %a "ON Direct on is active "OFF Direct on is inactive Unacceptable "Error code"[CR] 9.11.17 CR_PTIMEMODE Command Command "CR_PTIMEMODE"[CR] Details Get operation mode of P-timer. Acceptable "000_%a"[CR] Response %a "COUNTUP Count up is selected "COUNTDN Count down is selected. Unacceptable "Error code"[CR] 9.11.18 CR_PTIMER Command Command "CR_PTIMER"[CR] Details Get current status of P-timer Acceptable "000_%a"[CR] "ON P-timer is in execution Response %a "STOP P-timer is paused "OFF P-timer is inactive Unacceptable "Error code"[CR] 65/72