PLC-WL2500 / WL2501/ WL2503 Expand Serial Command Functional Specifications 9.5.6 CR_DDOTS Command Command "CR_DDOTS"[CR] Details Get Display Dots value Acceptable "000_%a"[CR] Response %a "0256"~"nnnn" (nnnn = Total Dots - Horizontal Position value) Unacceptable "Error Code"[CR] 9.5.7 CR_DLINE Command Command "CR_DLINE"[CR] Details Get Display Line value Acceptable "000_%a"[CR] Response %a "0100"~"nnnn" (nnnn = Total Line - Vertical Position value) Unacceptable "Error Code"[CR] 9.5.8 CR_PCSTORE Command Command "CR_PCSTORE"[CR] Details Get Free/Stored status of MODE1 - MODE10 for PC Adjust The data consists of 10 bytes and each byte indicates the status of MODE1 ~ MODE10 respectively. (F:Free S:Stored) Acceptable "000_%a"[CR] Response Requested data "FFFFFFFFFF All Free "SFFFFFFFFF MODE1 is Stored, others are Free : "FFFFFFFFFS MODE10 is Stored, others are Free "SSSSSSSSSS All Stored Unacceptable "Error code"[CR] 51/72