Sanyo PLC-WL2503 RS232C Expand - Page 69
CR_DELAYCTRL Command, 11.30 CR_FILH Command, 11.31 CR_FILREPL Command, 11.32 CR_FILTIMER
![]() |
UPC - 086483079627
View all Sanyo PLC-WL2503 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 69 highlights
PLC-WL2500 / WL2501/ WL2503 Expand Serial Command Functional Specifications 9.11.29 CR_DELAYCTRL Command Command "CR_DELAYCTRL"[CR] Details Get setting status of Video delay control Acceptable "000_%1"[CR] Response %1 "ON Video delay control is active "OFF Video delay control is inactive Unacceptable "Error Code"[CR] 9.11.30 CR_FILH Command Command "CR_FILH"[CR] Details Get Filter used time Acceptable "000_%1"[CR] Response %1 "00000"~"99999 0 hour to 99999 hours Unacceptable "Error Code"[CR] 9.11.31 CR_FILREPL Command Command "CR_FILREPL"[CR] Details Get the information of Filter replacement time Acceptable "000_%1"[CR] Response %1 "1Y Over filter replacement time "1N Within filter replacement time Unacceptable "Error Code"[CR] 9.11.32 CR_FILTIMER Command Command "CR_FILTIMER" [CR] Details Get setting time which filter warning OSD is displayed Acceptable "000_%1"[CR] "2000 2000 hours Response %1 "3000 3000 hours "4000 4000 hours "OFF No OSD display Unacceptable "Error Code"[CR] 68/72
![](/manual_guide/products/sanyo-plcwl2503-rs232c-expand-d2dcdde/69.png)