Sanyo PLC-WL2503 RS232C Expand - Page 40

CF_P-MANETIME Command, 10.18 CF_ON-STA Command, 10.19 CF_PTIMEMODE Command, 10.20 CF_PTIMER

Page 40 highlights

PLC-WL2500 / WL2501/ WL2503 Expand Serial Command Functional Specifications 8.10.17 CF_P-MANETIME Command Command "CF_P-MANETIME_%1"[CR] "01" ~ "30 Directly select setting time by the minute "UP Plus one minute (01 → 02 → → 30 → 01) "DN Minus one minute(30 → 29 → → 01 → 30) Details Set Power Management time The status set by this command is stored in EEPROM and its setting is effective after ALL is OFF This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 8.10.18 CF_ON-STA Command Command "CF_ON STA_%1"[CR] "ON Set Direct on active "OFF Set Direct on inactive %1 "UP Switch setting (On → Off → On → ) "DN Switch setting (On → Off → On → ) Note) "UP" and "DN" behave the same. Details Set/Cancel Power ON Start The status set by this command is stored in EEPROM and its setting is effective after ALL is OFF This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 8.10.19 CF_PTIMEMODE Command Command "CF_PTIMEMODE_%1"[CR] %1 "COUNTUP Select Count up "COUNTDN Select Countdown Details Set operation mode of P-timer. The status set by this command is stored in EEPROM and its setting is effective after ALL is OFF This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 8.10.20 CF_PTIMER Command Command "CF_PTOMER_%1"[CR] "START Execute P-timer "STOP Pause P-timer %1 "RESTART Restart P-timer "RST Reset P-timer "EXIT Terminate P-timer function Details Control P-timer. This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 39/72

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73

PLC-WL2500 / WL2501/ WL2503
Expand Serial Command Functional Specifications
39/72
8.10.17 CF_P-MANETIME Command
Command
“CF_P-MANETIME_%1”[CR]
��
“01” ~ ”30” ----------------------- Directly select setting time by the minute
“UP” ------------------------------- Plus one minute (01
02
���
30
01)
“DN” ------------------------------- Minus one minute(30
29
���
01
30)
Details
Set Power Management time
The status set by this command is stored in EEPROM and its setting is effective
after ALL is OFF
This command is available in normal Power ON status.
Acceptable
“000”[CR]
Response
Unacceptable
“Error Code”[CR]
8.10.18 CF_ON-STA Command
Command
“CF_ON
STA_%1”[CR]
%1
“ON” --------------------------- Set Direct on active
“OFF” ------------------------- Set Direct on inactive
“UP” --------------------------- Switch setting (On
Off
On
���
)
“DN” --------------------------- Switch setting (On
Off
On
���
)
Note) “UP” and “DN” behave the same.
Details
Set/Cancel Power ON Start
The status set by this command is stored in EEPROM and its setting is effective
after ALL is OFF
This command is available in normal Power ON status.
Acceptable
“000”[CR]
Response
Unacceptable
“Error Code”[CR]
8.10.19 CF_PTIMEMODE Command
Command
“CF_PTIMEMODE_%1”[CR]
%1
“COUNTUP” ---------------- Select Count up
“COUNTDN” ---------------- Select Countdown
Details
Set operation mode of P-timer.
The status set by this command is stored in EEPROM and its setting is effective
after ALL is OFF
This command is available in normal Power ON status.
Acceptable
“000”[CR]
Response
Unacceptable
“Error Code”[CR]
8.10.20 CF_PTIMER Command
Command
“CF_PTOMER_%1”[CR]
%1
“START” ----------------------- Execute P-timer
“STOP” ------------------------ Pause P-timer
“RESTART” ------------------ Restart P-timer
“RST” -------------------------- Reset P-timer
“EXIT” -------------------------- Terminate P-timer function
Details
Control P-timer.
This command is available in normal Power ON status.
Acceptable
“000”[CR]
Response
Unacceptable
“Error Code”[CR]