Page 23 highlights
Connecting Multiple Monitors (Continued) 56 Use by selecting "INPUT2 Select" and setting INPUT2 to "Output". Example: 3 2 1 PC (ANALOG) INPUT INPUT 3/PC (ANALOG) OUTPUT PC(ANALOG) INPUT (Red: audio right) (White: audio left) INPUT 2 (INPUT/ OUTPUT) RGB cable To video output terminal PC audio cable To PC audio output terminal RGB cable shows the signal flow. I Monitors can be externally controlled using the RS-232C interface (COM port) of a PC, and, in this case too, multiple monitors can be connected in a daisy chain. By assigning each monitor an ID number (see page 56), you can perform input switching, adjustment and status monitoring of individual monitors. "First monitor "Second monitor "PC RS-232C cross cable To COM port To RS-232C INPUT terminal Related topic: 37 PC Operation US 22 RS-232C cross cable To RS-232C OUTPUT terminal To RS-232C INPUT terminal To RS-232C OUTPUT terminal