Sharp LC-M3700 LC-M3700 Operation Manual - Page 44

<Response format in, Advanced operation &gt

Page 44 highlights

PC Operation (Continued) I Normal response 1Response when no ID number has been set. Carriage return code (0DH, 0AH) OK↵ A response is returned when execution of the pertinent command is finished. 2Response when an ID number has been set. Space (20H) Carriage return code (0DH, 0AH) O K SPC 0 0 1 ↵ ID number of responding monitor I When a command has not been executed correctly* 1Response when no ID number has been set. Carriage return code (0DH, 0AH) ERR↵ 2Response when an ID number has been set. Space (20H) Carriage return code (0DH, 0AH) E R R SPC 0 0 1 ↵ ID number * This is returned when there is no such command, or when the command cannot be used in the current state of the monitor (i.e. video auto-adjustment with video display). * If communication has not been established for reasons like a bad connection with the monitor, nothing is returned (not even ERR). * If no monitor has been assigned the designated ID number (e.g. if the command IDSL0002[X] is issued, but no monitor with ID=002 is found), ERR XXX[X] is returned. (ID number at the furthest end) [Example] PC Set 1 Set 2 Set 3 PC Operation In the above case IDSL0004 ←Non-existent ID number WAIT ERR 003 ←Monitor with ID=3 at the furthest end returns ERR Continued on the next page. 43 US

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73

43
US
PC Operation
<Response format in
Advanced operation >
Normal response
1
Response when no ID number has been set.
O
Carriage return code
(0D
H
, 0A
H
)
K
A response is returned when execution of the
pertinent command is finished.
2
Response when an ID number has been set.
O
ID number of
responding monitor
Carriage return code
(0D
H
, 0A
H
)
K
SPC
0
0
1
Space (20
H
)
When a command has not been executed correctly*
1
Response when no ID number has been set.
E
Carriage return code
(0D
H
, 0A
H
)
R
R
2
Response when an ID number has been set.
E
Carriage return code
(0D
H
, 0A
H
)
R
R
SPC
0
0
1
ID number
Space (20
H
)
* This is returned when there is no such command, or when the command cannot be used in the
current state of the monitor (i.e. video auto-adjustment with video display).
* If communication has not been established for reasons like a bad connection with the monitor,
nothing is returned (not even ERR).
* If no monitor has been assigned the designated ID number (e.g. if the command IDSL0002[X] is
issued, but no monitor with ID=002 is found), ERR
XXX[X] is returned.
Continued on the next page.
PC Operation (Continued)
(ID number at the furthest end)
In the above case
IDSL0004
Non-existent ID number
WAIT
ERR
003
Monitor with ID=3 at the furthest end returns ERR
PC
Set 1
Set 2
Set 3
[Example]