Sharp LC-M3700 LC-M3700 Operation Manual - Page 38
PC Operation, PC connection, Communication conditions
View all Sharp LC-M3700 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 38 highlights
PC Operation PC connection 1 One-to-one connection with a PC ....... Basic operation Connect with RS-232C cross cable between the PC COM port (RS-232C connector) and the RS232C INPUT terminal on the back of monitor. "Rear view To RS-232C INPUT terminal To COM port "PC RS-232C cross cable 2 Daisy chain connection from a single PC....... Advanced operation Connect with RS-232C cross cable between the PC COM port (RS-232C connector) and the RS- 232C INPUT terminal on the back of monitor. Next, connect RS-232C cross cable to the first monitor's RS-232C OUTPUT terminal and to second monitor's RS-232C INPUT terminal. Connect in the same way to the third and subsequent monitors. Up to about 20 monitors can be connected, depending on the length of RS-232C cables and installation environment. "First monitor "Second monitor Basic Operation PC Operation "PC RS-232C cross cable To COM port To RS-232C INPUT terminal RS-232C cross cable To RS-232C OUTPUT terminal To RS-232C INPUT terminal To RS-232C OUTPUT terminal Communication conditions I Set the RS-232C communication settings on the PC to match the monitor's communication settings. Baud rate: Data length: Parity bit: 9,600 bps 8 bits None Stop bit: Flow control: 1 bit None 37 US