If you forget your PIN
View all Sharp LC-M3700 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 61 highlights
Settings and Adjustments (Continued) [Example: 4] Disabling remote control, monitor buttons and power operations (RS-232C daisy-chain connection) Note: Values returned by monitors are omitted because they vary depending on the number of connected monitors. PCL+xxxx LREM001+ LBTN001+ LPOW001+ PSE+xxxx ←("xxxx" is the current PIN. "xxxx" is not necessary if no PIN is set.) ←Locks remote control ←Locks monitor buttons ←Locks power operation ←("xxxx" is new PIN.) [Example: 5] Disabling remote control operation, operation using monitor buttons, and switching to the power standby state using those controls for a specific monitor (example: ID=2) in a chain of monitors connected via RS-232C. Note: Response messages are omitted for convenience as the number of connected monitors varies. IDLK0002 PCLRxxxx LREM0001 LBTN0001 LPOW0001 PSETxxxx IDLK0000 ←Select monitor with ID=2 ←("xxxx" is the current PIN. "xxxx" is not necessary if no PIN is set.) ←Locks remote control ←Locks monitor buttons ←Locks power operation ←("xxxx" is new PIN.) ←Exit "IDLK" command If you forget your PIN If you forget the PIN which you yourself set, perform the following operation when the PIN input screen is displayed. \ | ENTER MENU This allows you to temporarily unlock the function. US 60