Sony PDWHR1 User Manual (PDW-HR1 Operation Manual Ed. 1 Rev. 2 for Version 2.0 - Page 170

Troubleshooting, Alarms

Page 170 highlights

Troubleshooting Alarms An alarm (warning message) appears in the time data display area when an operation is attempted which is inappropriate for the settings on this unit or the state of the disc. Both the alarm message and the action to take to resolve the problem appear in the video monitor screen and on the screen of the external video monitor connected to the unit. Example alarm in time data display area ALARM REMOTE MODE IS SELECTED. SET REMOTE/LOCAL/NETWORK SWITCH TO LOCAL. Example alarm in video monitor screen When an alarm is displayed, remove the alarm cause by following the action to take. If the alarm display does not disappear, contact a Sony service representative. Please note that there are some alarms which do not appear depending on the setting of setup menu item 016 ALARM DISPLAY (see page 136). See "Setup Menu" (page 133) for more information about setup menu operations. When the unit is powered on Alarm message in time data display area ADJ. Mode! MENU Ver.UP ILL. SETUP! Exchg batt! Update Err! Alarm message in video monitor screen Description/action THE UNIT IS IN ADJUSTMENT MODE. CHECK THE SWITCHES OF S2200 ON THE HPR-31 BOARD AND S500 ON THE NET-5 BOARD. This appears when the unit is in adjustment mode. Contact a Sony service representative. THE SETUP MENU SOFTWARE HAS BEEN UPGRADED. SET THE SETUP MENU ITEMS TO THE DESIRED SETTINGS. Reset the settings in the setup menu (see page 139). INVALID SETTINGS SELECTED IN SETUP MENU. SET ITEMS IN THE SETUP MENU TO THE APPROPRIATE VALUES. CONTACT SERVICE IF THIS ALARM APPEARS AGAIN AFTER ABOVE PROCEDURE. Reset the settings in the setup menu (see page 139). If the same message appears after you reset the settings, contact a Sony service representative. BATTERY NEEDS REPLACING. PLEASE CONTACT SERVICE. The NVRAM battery is exhausted. Contact a Sony service representative. RUN SOFTWARE UPDATE PROGRAM. The software version is not properly updated. Update the software version again. If the same message appears after you update the software version, contact a Sony service representative. Appendix 170 Troubleshooting

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199

170
Troubleshooting
Appendix
Troubleshooting
Alarms
An alarm (warning message) appears in the time data
display area when an operation is attempted which is
inappropriate for the settings on this unit or the state of the
disc. Both the alarm message and the action to take to
resolve the problem appear in the video monitor screen and
on the screen of the external video monitor connected to
the unit.
When an alarm is displayed, remove the alarm cause by
following the action to take. If the alarm display does not
disappear, contact a Sony service representative.
Please note that there are some alarms which do not appear
depending on the setting of setup menu item 016 ALARM
DISPLAY
(see page 136)
.
See “Setup Menu” (page 133) for more information about
setup menu operations.
When the unit is powered on
ALARM
REMOTE MODE IS SELECTED.
SET REMOTE/LOCAL/NETWORK
SWITCH TO LOCAL.
Example alarm in time data display area
Example alarm in video monitor screen
Alarm message in time
data display area
Alarm message in video monitor screen
Description/action
ADJ. Mode!
THE UNIT IS IN ADJUSTMENT MODE.
CHECK THE SWITCHES OF S2200 ON THE
HPR-31 BOARD AND S500 ON THE NET-5
BOARD.
This appears when the unit is in adjustment
mode.
Contact a Sony service representative.
MENU Ver.UP
THE SETUP MENU SOFTWARE HAS BEEN
UPGRADED.
SET THE SETUP MENU ITEMS TO THE
DESIRED SETTINGS.
Reset the settings in the setup menu
(see
page 139)
.
ILL. SETUP!
INVALID SETTINGS SELECTED IN SETUP
MENU.
SET ITEMS IN THE SETUP MENU TO THE
APPROPRIATE VALUES. CONTACT SERVICE
IF THIS ALARM APPEARS AGAIN AFTER
ABOVE PROCEDURE.
Reset the settings in the setup menu
(see
page 139)
. If the same message appears after
you reset the settings, contact a Sony service
representative.
Exchg batt!
BATTERY NEEDS REPLACING. PLEASE
CONTACT SERVICE.
The NVRAM battery is exhausted. Contact a
Sony service representative.
Update Err!
RUN SOFTWARE UPDATE PROGRAM.
The software version is not properly updated.
Update the software version again. If the same
message appears after you update the software
version, contact a Sony service representative.