Yamaha AW1600 Owner's Manual - Page 171

Using the AW1600 with external devices, Using the AW1600 with a \

Page 171 highlights

Chapter 15 Using the AW1600 with external devices This chapter describes various examples of how you can use the AW1600 in conjunction with external devices. Using the AW1600 with a "workstation synth" There are numerous ways in which you can use the AW1600 together with a workstation synthesizer (a synthesizer that has a built-in sequencer). Synchronizing the AW1600 with the workstation's sequencer Here's how you can use MTC to synchronize the AW1600 song with the sequencer built into your workstation synth. In this example we will also use MMC to remotely control the transport of the AW1600 from your workstation synth. 1 Refer to the following diagram, and connect the AW1600 to your workstation synthesizer. AW1600 MTC MIDI OUT MIDI IN MIDI IN MIDI OUT MMC REC SONG SCENE MUSIC PRODUCTION SYNTHESIZER Integrated Sampling Sequencer Real-time External Control Sur face Modular Synthesis Plug-in System Synthesizer with built-in sequencer 2 In the Work Navigate section, use the [UTILITY] key to access the MIDI 1 page of the UTILITY screen. Set the IN PORT and OUT PORT to MIDI. 3 In the Work Navigate section, use the [UTILITY] key to access the MIDI 2 page of the UTILITY screen. Turn on the SLAVE button in the MMC MODE field, and turn on the MASTER button in the MTC MODE field. The AW1600 will be set to function as MMC slave and MTC master. ● Example settings for synchronization using MTC and MMC 5 In the Work Navigate section, use the [SONG] key to access the SETUP page of the SONG screen, and select a frame rate in the TIME CODE BASE area. HINT • The frame rate you specify here will affect not only synchronization with the external device, but also the time code that is displayed in the counter, etc. 6 Set your workstation synth to function as MMC master and MTC slave, and set its MMC device number and MTC frame rate to the same settings as the AW1600. For details on how to make these settings, refer to the manual for your workstation synth. 7 Play back the sequencer (of your workstation synth). When you play back the sequencer of your workstation synth, the corresponding MMC commands will be sent to the AW1600, and the AW1600 will begin running. At the same time, the AW1600 will transmit MTC to your workstation synth, and the sequencer will run in synchronization with it. HINT • You can synchronize using MIDI Clock and Start/Stop/Continue messages instead of using MTC and MMC. For details on the settings in this case, refer to the section that follows, "Recording/playing AW1600 mix operations on the workstation's sequencer." Using the AW1600 with external devices 15 4 Move the cursor to the DEV field, and set the value to match the device number of your workstation synthesizer. When using MMC, you must set the AW1600 and the external MIDI device to the same MMC device number. For details on the device numbers that your workstation synth can use, refer to its owner's manual. AW1600 Owner's Manual 171

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232

171
AW1600
Owner’s Manual
15
Using the AW1600 with external devices
Chapter 15
Using the AW1600 with external devices
This chapter describes various examples of how you can use the AW1600 in
conjunction with external devices.
There are numerous ways in which you can use the AW1600 together with a workstation synthe-
sizer (a synthesizer that has a built-in sequencer).
Here’s how you can use MTC to synchronize the AW1600
song with the sequencer built into your workstation synth.
In this example we will also use MMC to remotely control
the transport of the AW1600 from your workstation synth.
1
Refer to the following diagram, and connect
the AW1600 to your workstation synthe-
sizer.
2
In the Work Navigate section, use the [UTIL-
ITY] key to access the MIDI 1 page of the
UTILITY screen. Set the IN PORT and OUT
PORT to MIDI.
3
In the Work Navigate section, use the [UTIL-
ITY] key to access the MIDI 2 page of the
UTILITY screen. Turn on the SLAVE button
in the MMC MODE field, and turn on the
MASTER button in the MTC MODE field.
The AW1600 will be set to function as MMC slave and
MTC master.
Example settings for synchronization using
MTC and MMC
4
Move the cursor to the DEV field, and set
the value to match the device number of
your workstation synthesizer.
When using MMC, you must set the AW1600 and the
external MIDI device to the same MMC device num-
ber. For details on the device numbers that your work-
station synth can use, refer to its owner’s manual.
5
In the Work Navigate section, use the
[SONG] key to access the SETUP page of
the SONG screen, and select a frame rate in
the TIME CODE BASE area.
6
Set your workstation synth to function as
MMC master and MTC slave, and set its
MMC device number and MTC frame rate to
the same settings as the AW1600.
For details on how to make these settings, refer to the
manual for your workstation synth.
7
Play back the sequencer (of your worksta-
tion synth).
When you play back the sequencer of your worksta-
tion synth, the corresponding MMC commands will be
sent to the AW1600, and the AW1600 will begin run-
ning.
At the same time, the AW1600 will transmit MTC to
your workstation synth, and the sequencer will run in
synchronization with it.
Using the AW1600 with a “workstation synth”
Synchronizing the AW1600 with
the workstation’s sequencer
MIDI OUT
MIDI IN
MIDI IN
MIDI OUT
AW1600
MTC
MMC
Synthesizer with
built-in sequencer
The frame rate you specify here will affect not only synchroni-
zation with the external device, but also the time code that is
displayed in the counter, etc.
HINT
You can synchronize using MIDI Clock and Start/Stop/Con-
tinue messages instead of using MTC and MMC. For details
on the settings in this case, refer to the section that follows,
“Recording/playing AW1600 mix operations on the worksta-
tion’s sequencer.”
HINT