ZyXEL Omni 56K USB Lite User Guide - Page 61

Table 5-12 Extended S-Registers ATSn=x, COMMAND, FUNCTION AND DESCRIPTION

Page 61 highlights

Omni 56K USB Lite COMMAND S10= S11= FUNCTION AND DESCRIPTION Sets duration, in tenths of a second, modem waits after loss of carrier before hanging up. Sets duration and spacing, in milliseconds of dialed Touch-Tones. +REF. +007 +070 Table 5-12 Extended S-Registers "ATSn=x" COMMAND BIT S13= Bit 1 S14= bit 1 S15= bit 7-5 S16= S17= Bit 4-1 5 DEC dec 2 dec 0 2 dec 0 32 64 dec 0 1 8 dec 0-30 0 32 HEX FUNCTION AND DESCRIPTION hex Bit-mapped register. 2 Capture modem manufacturer information during V.42 handshake, can be displayed at ATI2 line if available ('Flash' or 'ZyXEL' stands for ZyXEL connection). hex Bit-mapped register: 0 Grant Remote Digital Loop-back test request. 2 Deny Remote Digital Loop-back test request. hex Bit-mapped register. 0 Profile 0 as active settings after power on. 20 Profile 1 as active settings after power on. 40 Factory default as active settings after power on. hex Test status register. 0 No test in progress. 1 Analog Loop-back test in progress. 8 Analog Loop-back with self-test in progress. hex Bit-mapped register. 0- Set transmit power level from 0 to -15 dBm. (See 1E also S35b3) (Default *P11) 0 Normal dial. (Default) 20 Reverse dial, go online in answer mode. REF. +000 +002 &T4 &T5* +066 Z0 Z1 Z2* +000 &T0 &T1 &T8 +022 *Pn D DR Command Sets 5-15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102

Omni 56K USB Lite
Command Sets
5-15
COMMAND
FUNCTION AND DESCRIPTION
+REF.
S10=
Sets duration, in tenths of a second, modem waits after loss of carrier
before hanging up.
+007
S11=
Sets duration and spacing, in milliseconds of dialed Touch-Tones.
+070
Table 5-12 Extended S-Registers "ATSn=x"
COMMAND
BIT
DEC
HEX
FUNCTION AND DESCRIPTION
REF.
Bit
dec
hex
Bit-mapped register.
+000
S13=
1
2
2
Capture modem manufacturer information during
V.42 handshake, can be displayed at ATI2 <Last
Speed/Protocol> line if available ('Flash' or
'ZyXEL' stands for ZyXEL connection).
bit
dec
hex
Bit-mapped register:
+002
0
0
Grant Remote Digital Loop-back test request.
&T4
S14=
1
2
2
Deny Remote Digital Loop-back test request.
&T5*
bit
dec
hex
Bit-mapped register.
+066
0
0
Profile 0 as active settings after power on.
Z0
32
20
Profile 1 as active settings after power on.
Z1
S15=
7-5
64
40
Factory default as active settings after power on.
Z2*
dec
hex
Test status register.
+000
0
0
No test in progress.
&T0
1
1
Analog Loop-back test in progress.
&T1
S16=
8
8
Analog Loop-back with self-test in progress.
&T8
Bit
dec
hex
Bit-mapped register.
+022
4-1
0-30
0-
1E
Set transmit power level from 0 to -15 dBm. (See
also S35b3) (Default *P11)
*Pn
0
0
Normal dial. (Default)
D
S17=
5
32
20
Reverse dial, go online in answer mode.
DR