Brother International FAX-1010 Service Manual - Page 120

Specifications

Page 120 highlights

Selector No. 1 2 3 4 5 6 7 8 WSW12 (Signal detection condition setting) Function Min. OFF time length of calling signal (Ci) Max. OFF time length of calling signal (Ci) Detecting time setting Delay Not used. Setting and Specifications No. 1 2 00 : 01 : 10 : 11 : No. 3 4 00 : 01 : 10 : 11 : No. 5 6 00 : 01 : 10 : 11 : 0: Yes 300 ms 500 ms 700 ms 900 ms 6 sec. 7 sec. 9 sec. 11 sec. 800 ms (1000 ms*) 200 ms 250 ms 150 ms 1: No * 1000 ms in Chinese or Hong Kong versions. • Selectors 1 through 4: Min. and max. OFF time length of calling signal (Ci) If the equipment detects the OFF state of calling signal (Ci) for a time length which is greater than the value set by selectors 1 and 2 and less than the value set by selectors 3 and 4, it interprets the Ci signal as OFF. • Selectors 5 and 6: Detecting time setting These selectors set the time length required to make the equipment acknowledge itself to be called. That is, if the equipment continuously detects calling signals with the frequency set by selectors 1 through 4 of WSW14 during the time length set by these selectors 5 and 6, it acknowledges the call. • Selector 7: Delay Setting this selector to "0" allows the equipment to insert a 900 ms WAIT after acknowledgement of the call until the equipment turns on the CML relay to start receiving operation.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216

WSW12
(Signal
detection
condition
setting)
Selector
No.
Function
Setting
and
Specifications
No.
1
2
1
Min.
OFF
time
length
of
calling
0
0
:
300
ms
signal
(Ci)
0
1
:
500
ms
2
1
0
:
700
ms
1 1
:
900
ms
No.
3
4
3
Max.
OFF
time
length
of
calling
signal
(Ci)
0
0
0
1
:
:
6
sec.
7
sec.
4
1
0
:
9
sec.
1 1
:
11
sec.
No.
5
6
5
0
0
:
800
ms
(1000
ms*)
Detecting
time
setting
0
1
:
200
ms
6
1
0
:
250
ms
1 1
:
150
ms
7
Delay
0:
Yes
1:
No
8
Not
used.
*
1000
ms
in
Chinese
or
Hong
Kong
versions.
Selectors
1
through
4:
Min.
and
max.
OFF
time
length
of
calling
signal
(Ci)
If
the
equipment
detects
the
OFF
state
of
calling
signal
(Ci)
for
a
time
length
which
is
greater
than
the
value
set
by
selectors
1
and
2
and
less
than
the
value
set
by
selectors
3
and
4,
it
interprets
the
Ci
signal
as
OFF.
Selectors
5
and
6:
Detecting
time
setting
These
selectors
set
the
time
length
required
to
make
the
equipment
acknowledge
itself
to
be
called.
That
is,
if
the
equipment
continuously
detects
calling
signals
with
the
frequency
set
by
selectors
1
through
4
of
WSW14
during
the
time
length
set
by
these
selectors
5
and
6,
it
acknowledges
the
call.
Selector
7:
Delay
Setting
this
selector
to
"0"
allows
the
equipment
to
insert
a
900
ms
WAIT
after
acknowledgement
of
the
call
until
the
equipment
turns
on
the
CML
relay
to
start
receiving
operation.