Brother International FAX-1010 Service Manual - Page 143
YShift
View all Brother International FAX-1010 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 143 highlights
3.6 Operational Check of Control Panel PCB • Function This function checks the control panel PCB for normal operation. • Operating Procedure (1) Press the 1 and 3 keys in this order in the initial maintenance mode. The "00 " will appear on the LCD. (2) Press the keys and buttons in the order designated in the illustration shown below. The LCD shows the corresponding number in decimal notation each time a key or button is pressed. Check that the displayed number is correct by referring to the illustration below. If a key or button is pressed out of order, the equipment beeps and displays the "INVALID OPERATE" on the LCD. To return to the status ready to accept key & button entry for operational check, press the Stop key. (3) After the last number key or button is pressed, the equipment beeps and returns to the initial maintenance mode. To terminate this operation, press the Stop key. The equipment returns to the initial maintenance mode. FAX1170/1270/1010/1020 Function Tet.index Resolution Mode Q.Scan Help 0 Hook ABC DEF .., 01 02 03 04 CO (1 .9(2!)(3 .9 Hold GHI JKL ., CO (4 ,,c) 50 6 C) 13 ex lA 15 ex 16 ei,, - 0 -) ( 0 ) CWTCW- ) OS 06 07 OS Redial / Pause PGRS TUY, WXYZ CO (_71) 8 0C9,0 17 , s,, 19 , s,, 19 ,,,,, 20 au C W- ) C W- ) C'19-) C reh '09 10 11 12 ' C) CLI(31)C03111C#31) SpeedDial C YShift21 ex 22 4c. 23 2A CW- ) CW- ) C@77C W-.) 1 Set Clear Sort Tel Enlarge/ Reduce C3 Copy 0 blather IntelliFAX 1270 PLAIN PAPER FACSIMILE Stop Sturt 0 0 Key & Button Entry Order (1)