WSW18 (Function setting 3) Selector No. 1 Function CCD manufacturer setting 2 Detection enabled time for CNG 3 and no tone 4 5 Not used. 6 Registration of station ID 7 Tone sound monitoring 8 Setting and Specifications Fixed to 1. No. 2 3 00 : 01 : 10 : 11 : 40 sec. 0 sec. (No detection) 5 sec. 80 sec. 0: Permitted 1: Prohibited No. 7 8 0X : 10 : 11 : No monitoring Up to phase B at the calling station only All transmission phases both at the calling and called stations • Selector 1: CCD manufacturer setting Reserved for future variation of CCD. • Selectors 2 and 3: Detection enabled time for CNG and no tone After the line is connected via the external telephone, the equipment can detect a CNG signal or no tone for the time length specified by these selectors. The setting specified by these selectors becomes effective only when selector 8 of WSW20 is set to "1." • Selector 6: Registration of station ID Setting this selector to "0" permits the registration of station ID for Austrian and Czecho versions. • Selectors 7 and 8: Tone sound monitoring These selectors sets monitoring specifications of the tone sound inputted from the line.