Cisco 7206VXR Configuration Guide - Page 82

Fan Failures, Configuration Fundamentals Configuration Guide, Configuration Fundamentals Command

Page 82 highlights

Functional Overview Chapter 1 Cisco 7200 VXR Product Overview Fan Failures Following is sample output of the show environment all command: NPE300(boot)# show environment all Power Supplies: Power Supply 1 is empty. Power Supply 2 is Zytek AC Power Supply. Unit is on. Temperature readings: chassis inlet measured at 26C/78F chassis outlet 1 measured at 28C/82F chassis outlet 2 measured at 29C/84F chassis outlet 3 measured at 33C/91F Voltage readings: +3.45 V measured at +3.46 V +5.15 V measured at +5.25 V +12.15 V measured at +12.24 V -11.95 V measured at -11.81 V Envm stats saved 138 time(s) since reload When the system power is on, all three fans should be operational. The system continues to operate if a fan fails; however, if the air temperature exceeds a defined threshold, the system controller displays warning messages on the console terminal, and if the temperature exceeds the shutdown threshold, the system controller shuts down the system. If the system does shut down because the temperature exceeded the shutdown threshold, the system displays the following message on the console screen and in the environment display when the system restarts: Queued messages: %ENVM-1-SHUTDOWN: Environmental Monitor initiated shutdown For complete descriptions and instructions for the environmental monitor commands, refer to the Configuration Fundamentals Configuration Guide and Configuration Fundamentals Command Reference publications, which are available on Cisco.com or the Documentation DVD. 1-64 Cisco 7200 VXR Installation and Configuration Guide OL-5013-09

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188

1-64
Cisco 7200 VXR Installation and Configuration Guide
OL-5013-09
Chapter 1
Cisco 7200 VXR Product Overview
Functional Overview
Following is sample output of the
show environment all
command:
NPE300(boot)#
show environment all
Power Supplies:
Power Supply 1 is empty.
Power Supply 2 is Zytek AC Power Supply. Unit is on.
Temperature readings:
chassis inlet
measured at 26C/78F
chassis outlet 1 measured at 28C/82F
chassis outlet 2 measured at 29C/84F
chassis outlet 3 measured at 33C/91F
Voltage readings:
+3.45 V
measured at +3.46 V
+5.15 V
measured at +5.25 V
+12.15 V
measured at +12.24 V
-11.95 V
measured at -11.81 V
Envm stats saved 138 time(s) since reload
Fan Failures
When the system power is on, all three fans should be operational. The system continues to operate if a
fan fails; however, if the air temperature exceeds a defined threshold, the system controller displays
warning messages on the console terminal, and if the temperature exceeds the shutdown threshold, the
system controller shuts down the system.
If the system does shut down because the temperature exceeded the shutdown threshold, the system
displays the following message on the console screen and in the environment display when the system
restarts:
Queued messages:
%ENVM-1-SHUTDOWN: Environmental Monitor initiated shutdown
For complete descriptions and instructions for the environmental monitor commands, refer to
the
Configuration Fundamentals Configuration Guide
and
Configuration Fundamentals Command
Reference
publications, which are available on Cisco.com or the Documentation DVD.