Compaq ProLiant 800 ProLiant 800 Servers Supporting Pentium II Processors and - Page 52
Check the cable, Replace the cables., Replace, If you do not want
View all Compaq ProLiant 800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 52 highlights
3-14 Diagnostic Tools POST Error Messages Continued Error Code Audible Beeps L=Long S=Short 1789-Drive Not None Responding, Physical Drive Check cables or replace physical drive X. Probable Source of Problem Cable or hard drive failure. Recommended Action 1. Check the cable 2. Replace the cables. 3. Replace 4. If you do not want to Select "F1" to continue - drive array will remain disabled. Select "F2" to fail drive(s) that are not responding - Interim Recovery Mode will be enabled if configured for fault tolerance. 1790-Disk 0 Configuration Error None Hard drive error or wrong Run the System Configuration Utility and drive type Diagnostics and correct. 1791-Disk 1 Error None Hard drive error or wrong Run the System Configuration Utility and drive type. Diagnostics and correct. 1792-Drive Array Reports Valid Data Found in Array Accelerator. Data will automatically be written to drive array. None This indicates that while the No action necessary; no data has been system was in use, power lost. Perform orderly system shutdowns was interrupted while data to avoid data remaining in the Array was in the Array Accelerator Accelerator. memory. Power was then restored within eight to ten days, and the data in the Array Accelerator was flushed to the drive array. Continued