Compaq ProLiant 800 ProLiant 800 Servers Supporting Pentium II Processors and - Page 52

Check the cable, Replace the cables., Replace, If you do not want

Page 52 highlights

3-14 Diagnostic Tools POST Error Messages Continued Error Code Audible Beeps L=Long S=Short 1789-Drive Not None Responding, Physical Drive Check cables or replace physical drive X. Probable Source of Problem Cable or hard drive failure. Recommended Action 1. Check the cable 2. Replace the cables. 3. Replace 4. If you do not want to Select "F1" to continue - drive array will remain disabled. Select "F2" to fail drive(s) that are not responding - Interim Recovery Mode will be enabled if configured for fault tolerance. 1790-Disk 0 Configuration Error None Hard drive error or wrong Run the System Configuration Utility and drive type Diagnostics and correct. 1791-Disk 1 Error None Hard drive error or wrong Run the System Configuration Utility and drive type. Diagnostics and correct. 1792-Drive Array Reports Valid Data Found in Array Accelerator. Data will automatically be written to drive array. None This indicates that while the No action necessary; no data has been system was in use, power lost. Perform orderly system shutdowns was interrupted while data to avoid data remaining in the Array was in the Array Accelerator Accelerator. memory. Power was then restored within eight to ten days, and the data in the Array Accelerator was flushed to the drive array. Continued

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129

3-14
Diagnostic Tools
POST Error Messages
Continued
Error Code
Audible Beeps
L=Long
S=Short
Probable Source of Problem
Recommended Action
1789-Drive Not
Responding,
Physical Drive
Check cables or
replace physical
drive
X
.
Select "F1" to
continue - drive
array will remain
disabled.
Select "F2" to fail
drive(s) that are not
responding -
Interim Recovery
Mode will be
enabled if configured
for fault tolerance.
None
Cable or hard drive failure.
1.
Check the cable
2.
Replace the cables.
3.
Replace
4.
If you do not want to
1790-Disk 0
Configuration Error
None
Hard drive error or wrong
drive type
Run the System Configuration Utility and
Diagnostics and correct.
1791-Disk 1 Error
None
Hard drive error or wrong
drive type.
Run the System Configuration Utility and
Diagnostics and correct.
1792-Drive Array
Reports Valid Data
Found in Array
Accelerator.
Data will
automatically be
written to drive
array.
None
This indicates that while the
system was in use, power
was interrupted while data
was in the Array Accelerator
memory. Power was then
restored within eight to ten
days, and the data in the Array
Accelerator was flushed to the
drive array.
No action necessary; no data has been
lost. Perform orderly system shutdowns
to avoid data remaining in the Array
Accelerator.
Continued