Compaq ProLiant 800 ProLiant 800 Servers Supporting Pentium II Processors and - Page 77
Message, Description, Recommended Action, Do not, System Configuration Utility.
View all Compaq ProLiant 800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 77 highlights
3-39 DAAD Diagnostic Messages Continued Message Description Configuration signature is zero DAAD detected that nonvolatile RAM contains a configuration signature that is zero. Old versions of the System Configuration Utility could cause this. Recommended Action Run the latest version of System Configuration Utility to configure the controller and nonvolatile RAM. Configuration signature mismatch Array accelerator board configured for a different array controller board. Configuration signature on array accelerator board does not match the one stored on the array controller board. To recognize the array accelerator board, run the System Configuration Utility. Controller communication failure occurred Controller communication failure occurred. DAAD was unable to successfully issue commands to the controller in this slot. Controller detected. NVRAM configuration not present EISA nonvolatile RAM does not contain a configuration for this controller. Run the System Configuration Utility to configure the nonvolatile RAM. Controller firmware needs upgrading Controller firmware is below the latest recommended version. Run Options ROMPaq to upgrade the controller to the latest firmware revision. Controller firmware needs upgrading (DAAD Error 102) Controller is correct, however, IDA firmware version should be greater than 1.26. Obtain the latest firmware. Controller is located in special "video" slot Controller is installed in slot for special video control signals. If controller is used in this slot, LED indicators on front panel may not function properly. Install the controller in a different slot and run the System Configuration Utility to configure the controller and nonvolatile RAM. Controller is not configured Controller is not configured. If controller was previously configured and you change drive locations, there may be a problem with placement of the drives. DAAD examines each physical drive and looks for drives that have been moved to a different drive bay. Look for messages indicating which drives have been moved. If none appear and drive swapping did not occur, run the System Configuration Utility to configure the controller and nonvolatile RAM. Do not run the System Configuration Utility if you believe drive swapping has occurred. Controller needs replacing (DAAD Error 102) IDA firmware is less than version 0.96. Replace the controller as soon as possible. Continued Compaq ProLiant 800 Servers Maintenance and Service Guide