Compaq ProLiant 800 ProLiant 800 Servers Supporting Pentium II Processors and - Page 53
Check that the Array, Accelerator is properly seated., Run the System Configuration
View all Compaq ProLiant 800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 53 highlights
3-15 POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem 1793-Drive Array - None This indicates that while the Array Accelerator system was in use, power was Battery Depleted - interrupted while data was in Data Lost the Array Accelerator memory. (Error message 1794 also displays.) Array Accelerator batteries failed. Data in Array Accelerator has been lost. Recommended Action Power was not restored within eight to ten days. Perform orderly system shutdowns to avoid data remaining in the Array Accelerator. 1794-Drive Array - None This is a warning that the Replace the Array Accelerator board if Array Accelerator battery charge is below 75%. batteries do not recharge within 36 Battery Charge Low. Posted-writes are disabled. power-on hours. Array Accelerator is temporarily disabled. Array Accelerator will be re-enabled when battery reaches full charge. 1795-Drive Array - None This indicates that while the Match the Array Accelerator to the Array Accelerator system was in use, power was correct drive array, or run the System Configuration Error. interrupted while data was in Configuration Utility to clear the data in Data does not the Array Accelerator memory. the Array Accelerator. correspond to this The data stored in the Array drive array. Array Accelerator does not correspond Accelerator is to this drive array. temporarily disabled. 1796-Drive Array - None Array Accelerator is defective or 1. Check that the Array Accelerator is properly seated. Array Accelerator Not has been removed. Responding. 2. Run the System Configuration Utility to reconfigure the Array Accelerator is temporarily disabled. Compaq IDA-2 without the Array Accelerator. 1797-Drive Array - None Hard parity error while reading Enable Array Accelerator. Array Accelerator data from posted-writes Read Error Occurred. memory. Data in Array Accelerator has been lost. Array Accelerator is disabled. Continued Compaq ProLiant 800 Servers Maintenance and Service Guide