Compaq ProLiant 800 ProLiant 800 Servers Supporting Pentium II Processors and - Page 99

Critical Error Log Messages, Message, Description

Page 99 highlights

3-61 Critical Error Log Messages Continued Message Description NMI - PCI Bus Parity Error A parity error was detected on the PCI bus. NMI - Expansion Board Error A board on the expansion bus indicated an error condition, resulting in a server failure. NMI - Expansion Bus Master A bus master expansion board in the indicated slot did not release the bus after its Time-Out maximum time, resulting in a server failure. NMI - Expansion Bus Slave A board on the expansion bus delayed a bus cycle beyond the maximum time, resulting in Time-Out a server failure. NMI - Fail-Safe Timer Expiration Software was unable to reset the system fail-safe timer, resulting in a server failure. Processor Exception The indicated processor exception occurred. NMI - Processor Parity Error The processor detected a data error, resulting in a server failure. Server Manager Failure An error occurred with the Server Manager/R. NMI - Software Generated Interrupt Detected Error Software indicated a system error, resulting in a server failure. Caution: Temperature Exceeded The operating system has detected that the temperature of the system has exceeded the caution level. Accompanying data in the log notes if an auto-shutdown sequence has been invoked by the operating system. Abnormal Program Termination The operating system has encountered an abnormal situation that has caused a system failure. ASR-2 Test Event The System Configuration Utility generated a test alert. NMI- Automatic Server Recovery Timer Expiration The operating system has received notice of an impending ASR-2 timer expiration. Required System Fan Failure The required system fan has failed. Accompanying data in the log notes if an autoshutdown sequence has been invoked by the operating system. UPS A/C Line Failure Shutdown or Battery Low The UPS notified the operating system that the AC power line has failed. Accompanying data indicates if an auto-shutdown sequence has been invoked or if the battery has been nearly depleted. ASR-2 detected by ROM An ASR-2 activity has been detected and logged by the system ROM. Compaq ProLiant 800 Servers Maintenance and Service Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129

3-61
Compaq ProLiant 800 Servers Maintenance and Service Guide
Critical Error Log Messages
Continued
Message
Description
NMI - PCI Bus Parity Error
A parity error was detected on the PCI bus.
NMI - Expansion Board Error
A board on the expansion bus indicated an error condition, resulting in a server failure.
NMI - Expansion Bus Master
Time-Out
A bus master expansion board in the indicated slot did not release the bus after its
maximum time, resulting in a server failure.
NMI - Expansion Bus Slave
Time-Out
A board on the expansion bus delayed a bus cycle beyond the maximum time, resulting in
a server failure.
NMI - Fail-Safe Timer
Expiration
Software was unable to reset the system fail-safe timer, resulting in a server failure.
Processor Exception
The indicated processor exception occurred.
NMI - Processor Parity Error
The processor detected a data error, resulting in a server failure.
Server Manager Failure
An error occurred with the Server Manager/R.
NMI - Software Generated
Interrupt Detected Error
Software indicated a system error, resulting in a server failure.
Caution: Temperature
Exceeded
The operating system has detected that the temperature of the system has exceeded the
caution level. Accompanying data in the log notes if an auto-shutdown sequence has been
invoked by the operating system.
Abnormal Program
Termination
The operating system has encountered an abnormal situation that has caused a
system failure.
ASR-2 Test Event
The System Configuration Utility generated a test alert.
NMI- Automatic Server
Recovery Timer Expiration
The operating system has received notice of an impending ASR-2 timer expiration.
Required System Fan Failure
The required system fan has failed. Accompanying data in the log notes if an auto-
shutdown sequence has been invoked by the operating system.
UPS A/C Line Failure
Shutdown or Battery Low
The UPS notified the operating system that the AC power line has failed. Accompanying
data indicates if an auto-shutdown sequence has been invoked or if the battery has been
nearly depleted.
ASR-2 detected by ROM
An ASR-2 activity has been detected and logged by the system ROM.